The AirTAC GFC300-15 Combination Unit (GFC30015C1TK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC30015C1TK is a two-unit air treatment set combining a filter regulator with a lubricator, and the K suffix means a reverse (check) valve is fitted, so downstream pressure is held if the upstream supply is lost. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
This is a genuine AirTAC part. The GFC family is offered in 200, 300, 400 and 600 sizes with your choice of port, thread, drain type, filter grade and gauge; flow is published as curves rather than a single rating, so we confirm datasheet figures on request.
| Model | AirTAC GFC300-15 Combination Unit (GFC30015C1TK) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/2" · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-15 |
| Build order | Filter regulator first, lubricator last |
Supplying quarter-turn pneumatic valve actuators in a paint booth line, the set delivers filtered, regulated and lubricated air, while the fitted check valve holds actuator pressure if the plant supply dips mid-stroke.
On a commercial-vehicle brake-test rig, the two-unit set conditions the shop air feeding test cylinders and gauges, and the reverse valve keeps the test circuit pressurised during brief compressor unloading cycles.
Feeding a pick-and-place robot's pneumatic gripper manifold, the set filters weld fume and moisture, regulates gripper pressure, lubricates the cylinders, and the check valve prevents backflow when the cell is isolated.
Choose this K version when a check valve matters: it holds the regulated downstream circuit against backflow, useful where a momentary supply drop would upset a process. The 300 size with NPT1/2 ports covers mid-range lines; move to 400 or 600 for larger ports and more flow. The 40 um element is standard, with a 5 um W option for finer filtration.
Drain is differential-pressure here; automatic (A) and manual (M) versions exist in the family. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves, not a single rating, so ask us to confirm sizing before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.
We do not quote a single rated flow because AirTAC publishes flow as performance curves, not one number. Send us your application details and we will confirm the flow data and sizing from the datasheet on request.
K means a reverse (check) valve is fitted, so downstream pressure is retained against backflow if the upstream supply drops. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.