verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-15 Combination Unit (GFC30015C2WT)

The AirTAC GFC300-15 Combination Unit (GFC30015C2WT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$80.56 $88.06Save 8% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC300-15 drain, gauge and thread option on one page All GFC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC300-15 Combination Unit (GFC30015C2WT)

GFC is AirTAC's two-unit air preparation set: a filter-regulator and a lubricator supplied as a matched pair, so one installation point delivers filtered, regulated and lubricated compressed air to the machine. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. It carries a round external pressure gauge scaled in psi, and the regulator adjusts from 0.15-0.9 MPa (20-130 psi) with this drain type. At the 300 size both bowls are polycarbonate (PC); maximum working pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part from the G series, which runs from the 200 size up to 600 so you can step port size to the line. Across the series you can order manual or automatic drain versions, G (BSPP) or NPT threads, and bracket mounting. Flow is published as curves rather than a single rating, so we confirm the figures and datasheet details for your application on request. Order code GFC30015C2WT has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GFC300-15 Combination Unit (GFC30015C2WT) Technical Specifications

ModelAirTAC GFC300-15 Combination Unit (GFC30015C2WT)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-15 Combination Unit (GFC30015C2WT)

GFC300G-series two-unit set, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/2" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-15
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-15 Combination Unit (GFC30015C2WT) Is Used

settings_input_component

Precision valve manifold

Feeds a manifold of directional control valves where the 5 um element helps keep spool clearances clear of fine particulate carried in the shop air.

handyman

Robotic welding cell

Supplies the solenoid valves and grip cylinders of a welding robot cell, with regulated pressure set at the cell inlet and lubrication for the actuated grippers.

science

Test rig instrument air

Conditions the air feeding instruments and actuated fixtures on a laboratory test rig, where the finer element and a stable regulated setting matter.

Is the AirTAC GFC300-15 Combination Unit (GFC30015C2WT) the Right Set?

This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. If your application tolerates coarser filtration, the non-W GFC30015 versions use the standard 40 um element. Drain is differential-pressure as coded, with manual (M) and automatic (A) versions available. The gauge is a round external unit reading psi; square gauges and MPa or bar scales are catalogue alternatives. Flow is published as curves, not a single rated number, so send us your demand and pressure and we will confirm sizing from the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.

AirTAC GFC300-15 Combination Unit (GFC30015C2WT) FAQ

AirTAC publishes G-series flow as performance curves rather than a single rated figure, so we do not quote a rated flow here. Tell us your required flow and working pressure and we will confirm sizing from the datasheet on request before you order.

The W code fits a 5 um filter element instead of the 40 um standard, so choose it when fine particulate could affect downstream valves or instruments. The regulation range, drain and ports are otherwise the same in this configuration.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC300-15 Combination Unit (GFC30015C2WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC30015C2WT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.