verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-15 Combination Unit (GFC30015F1WT)

The AirTAC GFC300-15 Combination Unit (GFC30015F1WT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$80.56 $88.06Save 8% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC300-15 drain, gauge and thread option on one page All GFC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC300-15 Combination Unit (GFC30015F1WT)

The AirTAC GFC series is a two-unit air preparation set: a filter regulator and a lubricator supplied as one matched pair. The filter regulator removes water and particulate from the compressed-air line and holds downstream pressure steady across a 0.15-0.9 MPa (20-130 psi) adjustment range, while the lubricator feeds a controlled oil mist to downstream tools and cylinders. This unit is the 300 size with a NPT1/2 port, a differential-pressure drain on the filter bowl, a 5 um W-grade filter element and an embedded square gauge scaled in MPa. Maximum working pressure is 1.0 MPa (145 psi), the service temperature range is -5 to 70 C (non-freezing), and the 300-size bowls are polycarbonate (PC).

This is a genuine AirTAC part sold by a distributor. The G series runs in 200, 300, 400 and 600 sizes with ports from 1/8" to 1", and G (BSPP) and NPT threads, automatic and manual drains and the standard 40 um element are catalogue options to order. Flow is published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your line before you order. Order code GFC30015F1WT has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GFC300-15 Combination Unit (GFC30015F1WT) Technical Specifications

ModelAirTAC GFC300-15 Combination Unit (GFC30015F1WT)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-15 Combination Unit (GFC30015F1WT)

GFC300G-series two-unit set, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/2" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-15
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-15 Combination Unit (GFC30015F1WT) Is Used

precision_manufacturing

CNC machining centre air supply

Mounted ahead of a CNC machining centre's air drop, the 5 um element strips finer particulate and condensed water from the shop supply, while the regulator holds pressure at the machine's valve stack and the lubricator mists the actuated circuits.

science

Laboratory autoclave and analyser feed

On a laboratory line feeding autoclaves and bench analysers, the set filters the compressed-air supply to 5 um, regulates it to the instrument manifold and oils downstream pneumatic laboratory fixtures.

conveyor_belt

Packaging line carton sealer

On a carton-sealing conveyor line, the unit feeds clean, regulated and lubricated air to the cylinder-driven flap folders and tape heads, with the 1/2" port supplying a downstream actuator manifold.

Is the AirTAC GFC300-15 Combination Unit (GFC30015F1WT) the Right Set?

Step between the 200, 300, 400 and 600 sizes to match port and flow demand; the 300 size carries a 1/2" port here. Choose the drain: differential-pressure (this model, standard), automatic for unattended draining, or manual for drain-on-demand. This model carries the W-code 5 um element for finer filtration than the 40 um standard; confirm which grade your downstream equipment calls for. The embedded square gauge comes scaled in MPa here, with psi and bar scales orderable. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves, not a single rating, so send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.

AirTAC GFC300-15 Combination Unit (GFC30015F1WT) FAQ

Flow for the G series is published as curves rather than a single rated figure, so there is no one number we can quote here. Send us your application details and we will confirm the sizing from the AirTAC datasheet on request.

W is the AirTAC code for the 5 um filter element, instead of the 40 um standard element fitted to units without the W. The grade applies to the filter side of the set only; the regulator and lubricator functions are unchanged.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC300-15 Combination Unit (GFC30015F1WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC30015F1WT and will confirm price, availability and lead time — usually within 7 hours.