The AirTAC GFC300-15 Combination Unit (GFC30015F1WTK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC series is a two-unit air preparation set: a filter regulator and a lubricator supplied as one matched pair. The filter regulator removes water and particulate from the compressed-air line and holds downstream pressure steady across a 0.15-0.9 MPa (20-130 psi) adjustment range, while the lubricator feeds a controlled oil mist to downstream tools and cylinders. This unit is the 300 size with a NPT1/2 port, a differential-pressure drain on the filter bowl, a 5 um W-grade filter element, an embedded square gauge scaled in MPa and a reverse (check) valve fitted. Maximum working pressure is 1.0 MPa (145 psi), the service temperature range is -5 to 70 C (non-freezing), and the 300-size bowls are polycarbonate (PC).
This is a genuine AirTAC part sold by a distributor. The G series runs in 200, 300, 400 and 600 sizes with ports from 1/8" to 1", and G (BSPP) and NPT threads, automatic and manual drains and the standard 40 um element are catalogue options to order. Flow is published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your line before you order. Order code GFC30015F1WTK has NPT ports (the T in the code) for North American pipe fittings.
| Model | AirTAC GFC300-15 Combination Unit (GFC30015F1WTK) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/2" · 5 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-15 |
| Build order | Filter regulator first, lubricator last |
Mounted ahead of a CNC machining centre's air drop, the 5 um element strips finer particulate and condensed water from the shop supply, while the regulator holds pressure at the machine's valve stack and the lubricator mists the actuated circuits.
On a laboratory line feeding autoclaves and bench analysers, the set filters the compressed-air supply to 5 um, regulates it to the instrument manifold and oils downstream pneumatic laboratory fixtures.
On a carton-sealing conveyor line, the unit feeds clean, regulated and lubricated air to the cylinder-driven flap folders and tape heads, with the 1/2" port supplying a downstream actuator manifold.
Step between the 200, 300, 400 and 600 sizes to match port and flow demand; the 300 size carries a 1/2" port here. Choose the drain: differential-pressure (this model, standard), automatic for unattended draining, or manual for drain-on-demand. This model combines the W-code 5 um element with the K-code reverse (check) valve; both are catalogue options you can order together or separately. The embedded square gauge comes scaled in MPa here, with psi and bar scales orderable. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves, not a single rating, so send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.
Flow for the G series is published as curves rather than a single rated figure, so there is no one number we can quote here. Send us your application details and we will confirm the sizing from the AirTAC datasheet on request.
W selects the 5 um filter element instead of the 40 um standard, and K fits a reverse (check) valve to the regulator side of the set. Both are independent catalogue options on GFC units, so you can order either, both or neither.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.