verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-15 Combination Unit (GFC30015LC1WT)

The AirTAC GFC300-15 Combination Unit (GFC30015LC1WT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$80.56 $88.06Save 8% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC300-15 drain, gauge and thread option on one page All GFC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC300-15 Combination Unit (GFC30015LC1WT)

The AirTAC GFC30015LC1WT is a two-unit compressed-air treatment set combining a filter regulator with a separate lubricator for filtration, regulation and oil-mist lubrication in one supply. Two suffixes define this build: L marks the low-pressure regulator type for lines running at a reduced set pressure, and W specifies the finer 5 um filter element in place of the 40 um standard. The C1 suffix adds the external round pressure gauge scaled in MPa. This size 300 unit has a NPT1/2 in. port and differential-pressure drain; maximum working pressure is 1.0 MPa (145 psi). Confirm the low-pressure type's adjustment range with us on request.

This is a genuine AirTAC part from the G-series, available in sizes 200 through 600 with 1/8 to 1 in. ports, G (BSPP) or NPT threads, all three drain types, both filter grades and standard or low-pressure regulators. Flow is published as curves rather than a single rating, so ask us to confirm sizing and full datasheet figures on request.

AirTAC GFC300-15 Combination Unit (GFC30015LC1WT) Technical Specifications

ModelAirTAC GFC300-15 Combination Unit (GFC30015LC1WT)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-15 Combination Unit (GFC30015LC1WT)

GFC300G-series two-unit set, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/2" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-15
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-15 Combination Unit (GFC30015LC1WT) Is Used

view_module

Electronics fixture clamping

Feeding low-pressure clamp and hold-down fixtures on an electronics assembly module, where the 5 um element protects small pilot valves and the lubricator keeps the short-stroke cylinders sealed and smooth.

valve

Instrument air take-off

Supplying air to pneumatic control valves and positioners that require reduced, finely filtered supply: the low-pressure regulator sets the gentle set point while the lubricator is fitted for the actuator circuit.

engineering

Test bench conditioning

Conditioning air on an engineering test bench running delicate low-pressure components: clean 5 um air, a controlled reduced pressure read on the round MPa gauge, and oil mist where lubricated motion is under test.

Is the AirTAC GFC300-15 Combination Unit (GFC30015LC1WT) the Right Set?

This code brings together the two main decode choices: the L low-pressure regulator type and the W 5 um filter element. Use it when downstream devices need both a reduced set pressure and finer filtration; drop the W for the 40 um standard element or the L for the standard regulator range. Size 300 with a NPT1/2 in. port is the G-series mid step - go to 400 or 600 for larger ports, or 200 for smaller. The differential-pressure drain drains automatically at high differential; manual (M) and automatic (A) are options. The round gauge reads in MPa, with other scales and the square gauge available. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G (BSPP) and NPT are order options.

Flow is published as curves, not a single rated figure, so ask us to confirm sizing against the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.

AirTAC GFC300-15 Combination Unit (GFC30015LC1WT) FAQ

Yes - on request. AirTAC publishes G-series flow as characteristic curves rather than a single rated figure, so we do not state one number as a rating. Give us your line pressure, set pressure and demand and we will confirm the sizing from the datasheet.

Two suffixes differ. The L makes this the low-pressure regulator type, for lines needing a reduced set pressure, while F3W is the standard type. The C1 gauge is the external round gauge in MPa, against the embedded square gauge in bar on F3. The W (5 um filter), NPT1/2 in. port and differential-pressure drain are common to both.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC300-15 Combination Unit (GFC30015LC1WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC30015LC1WT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.