The AirTAC GFC300-15 Combination Unit (GFC30015MF1TK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).
GFC30015MF1TK is an AirTAC G-series two-unit F.R.L. set pairing a filter-regulator in one body with a separate lubricator for combined filtration, regulation and oil-mist lubrication. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Maximum working pressure is 1.0 MPa (145 psi); the manual-drain regulator adjusts from 0.05 to 0.9 MPa (7-130 psi).
This is a genuine AirTAC part. The GFC family is available in 200/300/400/600 sizes with ports from 1/8 in to 1 in, 40 um standard or 5 um W filtration, differential-pressure, automatic or manual drains, square or round gauges with MPa, psi or bar scales, and the reverse-valve option; Flow is published as curves, not a single rating, so we confirm datasheet figures on request.
| Model | AirTAC GFC300-15 Combination Unit (GFC30015MF1TK) |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · PT1/2" · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-15 |
| Build order | Filter regulator first, lubricator last |
Air preparation for the diverter and pusher cylinders on a distribution-center sortation conveyor, where the check valve stops the energized circuit from back-feeding through the set.
Filtered, regulated, lubricated air to the part-ejection and clamp circuits of a metal stamping press cell, read and set on the MPa-scale square gauge.
Lubricated air supply at heavy-equipment service bays feeding pneumatic impact tools and chassis work, with the regulator set to the shop's standard working pressure.
Use the 300 size with 1/2 in NPT port on 1/2 in distribution at mid-range duty; step to 400 or 600 for bigger circuits or 200 for 1/8-1/4 in lines. Manual drain (M) delivers the wider 0.05-0.9 MPa (7-130 psi) regulation range but needs a hand-drain routine; choose automatic drain where maintenance rounds are impractical. The 40 um element is the standard general-line grade, with 5 um (W) as the finer alternative. The square MPa gauge is the embedded type; a round external gauge or psi/bar scales can be ordered instead. Specify the K reverse (check) valve exactly where backflow through the set must be blocked, and omit it elsewhere. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow appears only as curves, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.
Flow for G-series units is published as characteristic curves rather than a single rated figure, so we do not state one l/min or SCFM number. Give us your line conditions and we will confirm the sizing against the GFC300 datasheet curves on request before you order.
K fits a reverse (check) valve, so downstream air cannot flow back through the set when the upstream supply is vented or drops. The same unit without K is GFC30015MF1. Specify K only on circuits where that backflow blocking is actually needed.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.