verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC400-10 Combination Unit (GFC40010AC1T)

The AirTAC GFC400-10 Combination Unit (GFC40010AC1T) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 40 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$137.82 $145.32Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC400-10 drain, gauge and thread option on one page All GFC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC400-10 Combination Unit (GFC40010AC1T)

The AirTAC GFC series pairs a filter regulator with a lubricator in a two-piece set covering filtration, pressure regulation and oil-mist lubrication. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. An external round pressure gauge with MPa scale is included, and the regulator adjusts outlet pressure across 0.15-0.9 MPa (20-130 psi). It runs on compressed air from -5 to 70 C (non-freezing) at up to 1.0 MPa (145 psi) inlet, with polycarbonate bowls on both sections.

This is a genuine AirTAC part. The G series runs from size 200 to 600 with ports from 1/8 in to 1 in, plus G (BSPP) and NPT thread variants, manual or differential drains, a 5 um element option, gauge choices and a check-valve option, so a matching set can be ordered for most lines. Flow is published as curves rather than a single rating; ask us to confirm the datasheet figures and sizing for your application. Order code GFC40010AC1T has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GFC400-10 Combination Unit (GFC40010AC1T) Technical Specifications

ModelAirTAC GFC400-10 Combination Unit (GFC40010AC1T)
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC400-10 Combination Unit (GFC40010AC1T)

GFC400G-series two-unit set, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-10 filter regulator and GL400-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT3/8" · 40 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-10
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC400-10 Combination Unit (GFC40010AC1T) Is Used

precision_manufacturing

Pick-and-place robotics

Point-of-use treatment for pick-and-place robot cells: the regulator sets cylinder and gripper pressure, the lubricator feeds the actuator air, and the round MPa gauge lets technicians verify the setting at a glance.

factory

Assembly plant air drops

Fits assembly-station air drops where the automatic drain clears condensate from the bowl on lines that run through breaks and shift changes without anyone bleeding the bowl by hand.

local_shipping

Truck service bay

Feeds impact wrenches, air jacks and inflation stations in a commercial-vehicle service bay, with the 3/8 in NPT ports matching typical shop drop hoses and the gauge showing regulated tool pressure.

Is the AirTAC GFC400-10 Combination Unit (GFC40010AC1T) the Right Set?

Size 400 with 3/8 in NPT ports suits medium plant-air and machine supply lines; move to size 300 for compact branches or size 600 where larger ports are needed. This version takes the automatic drain (A) for hands-off condensate removal, while the standard differential-pressure drain and the manual drain (M) remain order choices. The element is the standard 40 um grade; specify W for 5 um. The external round gauge reads in MPa; square gauges and psi or bar scales can be ordered. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-10 filter regulator on its own.

AirTAC GFC400-10 Combination Unit (GFC40010AC1T) FAQ

There is no single rated flow figure: AirTAC publishes G-series performance as flow curves. Send us your working pressure and air consumption and we will confirm the correct size from the datasheet on request.

A specifies an automatic drain, which empties the filter bowl without manual attention. The alternatives are the standard differential-pressure drain or a manual drain (M) - note that manual-drain versions regulate across 0.05-0.9 MPa (7-130 psi), while this automatic-drain set regulates 0.15-0.9 MPa (20-130 psi).

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC400-10 Combination Unit (GFC40010AC1T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC40010AC1T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.