verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC400-10 Combination Unit (GFC40010NT)

The AirTAC GFC400-10 Combination Unit (GFC40010NT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$116.72 $124.22Save 6% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC400-10 drain, gauge and thread option on one page All GFC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC400-10 Combination Unit (GFC40010NT)

GFC40010NT is a genuine AirTAC GFC two-unit air preparation set: a filter regulator and a lubricator supplied as a matched pair for one 3/8 in NPT ported line. The filter-regulator section removes water and particulate down to the standard 40 um grade and holds downstream pressure anywhere in the 0.15-0.9 MPa (20-130 psi) adjustment window that applies with the differential-pressure drain fitted. The N suffix means no gauge is included. Size 400 handles compressed air only, with a maximum inlet pressure of 1.0 MPa (145 psi), a working range of -5 to 70 C (non-freezing), and a polycarbonate bowl on the filter-regulator section.

This is a genuine AirTAC part in the G series, which spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in and thread options three thread types (NPT on this code). Filter grade (40 um standard, 5 um optional), drain type, gauge and reverse-check valve are all orderable variants. AirTAC publishes flow as curves rather than a single rated figure, so we confirm the datasheet and flow data for your application on request.

AirTAC GFC400-10 Combination Unit (GFC40010NT) Technical Specifications

ModelAirTAC GFC400-10 Combination Unit (GFC40010NT)
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC400-10 Combination Unit (GFC40010NT)

GFC400G-series two-unit set, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-10 filter regulator and GL400-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT3/8" · 40 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-10
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC400-10 Combination Unit (GFC40010NT) Is Used

precision_manufacturing

CNC machining-center clamp circuits

Feeds filtered, regulated and lubricated air to the vise and pallet-clamp cylinders of a CNC machining center, holding a set clamp pressure through the whole cycle.

conveyor_belt

Packaging conveyor diverters

Supplies the diverter and stopper cylinders on a packaging conveyor line; the lubricator conditions the downstream valves and cylinder seals in continuous duty.

handyman

Fleet-service bay air tools

Prepares shop air at a truck or bus maintenance bay so impact wrenches and ratchets on the service line receive clean, regulated, oil-misted air.

Is the AirTAC GFC400-10 Combination Unit (GFC40010NT) the Right Set?

Size 400 with a 3/8 in NPT port sits mid-range in the G series; move to size 300 (smaller ports) or size 600 (larger ports) only against a confirmed flow requirement, since AirTAC publishes flow as curves and not as a single rating. This set already combines filtering and regulating in one body plus a separate lubricator; if you want three separate bodies instead, the GC series is the equivalent three-piece F.R.L. The 40 um element is the standard grade; choose the W variant for 5 um filtration. No gauge is fitted on this code, and gauge variants with different scales are available in the family. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Ask us to confirm sizing and the datasheet against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-10 filter regulator on its own.

AirTAC GFC400-10 Combination Unit (GFC40010NT) FAQ

AirTAC publishes flow for the G series as curves, not as a single rated figure, so we do not quote a number on this page. Send us your line pressure and air demand and we will confirm the datasheet and curve data for this exact set on request before you order.

GFC is a two-piece set: a combined filter regulator plus a separate lubricator, so filtering and regulating happen in one body. GC is a three-piece combination with separate filter, regulator and lubricator bodies. Both filter, regulate and lubricate; GFC saves space and joints, while GC gives each function its own bowl.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC400-10 Combination Unit (GFC40010NT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC40010NT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.