verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC400-10 Combination Unit (GFC40010NTK)

The AirTAC GFC400-10 Combination Unit (GFC40010NTK) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$131.66 $139.16Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC400-10 drain, gauge and thread option on one page All GFC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC400-10 Combination Unit (GFC40010NTK)

GFC40010NTK is a genuine AirTAC GFC two-unit air preparation set: a filter regulator and a lubricator supplied as a matched pair for one 3/8 in NPT ported line, with a reverse (check) valve fitted as indicated by the K suffix. The filter-regulator section removes water and particulate down to the standard 40 um grade and holds downstream pressure anywhere in the 0.15-0.9 MPa (20-130 psi) adjustment window that applies with the differential-pressure drain fitted. The N suffix means no gauge is included. Size 400 handles compressed air only, with a maximum inlet pressure of 1.0 MPa (145 psi), a working range of -5 to 70 C (non-freezing), and a polycarbonate bowl on the filter-regulator section.

This is a genuine AirTAC part in the G series, which spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in and thread options three thread types (NPT on this code). Filter grade (40 um standard, 5 um optional), drain type, gauge and reverse-check valve are all orderable variants. AirTAC publishes flow as curves rather than a single rated figure, so we confirm the datasheet and flow data for your application on request.

AirTAC GFC400-10 Combination Unit (GFC40010NTK) Technical Specifications

ModelAirTAC GFC400-10 Combination Unit (GFC40010NTK)
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC400-10 Combination Unit (GFC40010NTK)

GFC400G-series two-unit set, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-10 filter regulator and GL400-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT3/8" · 40 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-10
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC400-10 Combination Unit (GFC40010NTK) Is Used

factory

Stamping-press part ejectors

Prepares air for the ejector and part-blow-off circuits on a stamping press line, with the check valve helping hold the set downstream pressure in the circuit.

view_module

Automated storage and retrieval cells

Conditions air for the gripper and lift actuators in an AS/RS storage cell, filtering, regulating and lubricating on a single 3/8 in supply.

valve

Pneumatic control-valve skids

Feeds pilot air to actuated process valves on a plant skid, keeping the set regulated pressure and a conditioned air supply to the pilot ports.

Is the AirTAC GFC400-10 Combination Unit (GFC40010NTK) the Right Set?

Size 400 with a 3/8 in NPT port sits mid-range in the G series; confirm your flow requirement with us before stepping between sizes, because AirTAC publishes flow as curves and not as a single rating. The K in this code means a reverse/check valve is fitted, which is the difference from the plain GFC40010N. The 40 um element is standard; the W variant gives 5 um filtration. No gauge is fitted on this code, and gauge variants with different scales exist in the family. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Ask us to confirm sizing and the datasheet against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-10 filter regulator on its own.

AirTAC GFC400-10 Combination Unit (GFC40010NTK) FAQ

AirTAC publishes flow for the G series as curves, not as a single rated figure, so we do not state a number here. Share your supply pressure and demand profile and we will confirm the datasheet and curve figures for this exact set on request before you order.

K indicates that a reverse (check) valve is fitted in this set. The otherwise identical code without K is supplied without the check valve, and gauge, filter grade and drain variants are also orderable in the family.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC400-10 Combination Unit (GFC40010NTK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GFC40010NTK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.