The AirTAC GFC600-20 Combination Unit (GFC60020ANT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/4" ports, a 40 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
GFC60020ANT is an AirTAC GFC two-unit set for compressed air: a 600-size filter regulator paired with a lubricator, covering filtration, pressure regulation and oil-mist lubrication in one order. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.
This is a genuine AirTAC part. The G series is built in 200, 300, 400 and 600 sizes with ports from 1/8 in. to 1 in. at 600 size the bowls are aluminium alloy, working pressure is up to 1.0 MPa (145 psi), temperature range is -5 to 70 C, and the regulator adjusts 0.15-0.9 MPa (20-130 psi) on this differential-pressure-drain version. Rated flow is published as curves rather than a single figure; ask us and we will confirm the datasheet figures for your application.
| Model | AirTAC GFC600-20 Combination Unit (GFC60020ANT) |
|---|---|
| Series | GFC600 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT3/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC600 | G-series two-unit set, 600 body — sets the port range. |
|---|---|
| 20 | Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR600-20 filter regulator and GL600-20 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC600 · PT3/4" · 40 µm |
|---|---|
| One size down | GFC400 |
| Three-unit equivalent | GC600-20 |
| Build order | Filter regulator first, lubricator last |
Runs the air motors that keep paint drums agitated with a filtered, regulated, lubricated supply, while pressure is read from a gauge already mounted on the room's control panel.
Feeds the stacker's pusher cylinders; the 40 um element and lubricator condition the air and the panel-mounted instrumentation covers pressure indication, so no gauge is needed on the unit.
Supplies riveting hammers and squeezers from a header line where shop gauges on the manifold already show line pressure; the set provides regulation and oil mist without duplicating them.
Choose 600 size with the NPT3/4 port when the circuit runs on 3/4 in. piping and draws a larger air volume. This code leaves the drain position blank, which is the differential-pressure drain - it suits lines with steady airflow, while A (automatic) or M (manual) are the other catalogue choices. The standard element grade is 40 um; add W for 5 um. N means no gauge is supplied - order the set without N for the embedded square gauge (MPa, psi or bar scale) if you want pressure on the unit itself. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G and NPT are options.
Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The aluminium-alloy bowls on the GFC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR600-20 filter regulator on its own.
AirTAC publishes G-series flow as curves, not a single rated number, so we do not state one here. Send us your operating pressure and air demand and we will confirm the datasheet curve figures for this 600-size, NPT3/4 set on request.
N means no gauge is supplied with the set. If you want pressure indication on the unit, order the version without N for the embedded square gauge, available with MPa, psi or bar scale; an external round gauge is also a catalogue option.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.