The AirTAC GFC600-20 Combination Unit (GFC60020C1WT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/4" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC60020C1WT is a genuine AirTAC two-unit air-treatment set: filter-regulator plus lubricator, with the W marking finer 5 um filtration instead of the standard 40 um grade. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Maximum working pressure is 1.0 MPa (145 psi), and the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi) with the differential-pressure drain.
This is a genuine AirTAC part in the largest G-series size, so the 600-size bowls are aluminium alloy. Temperature range is -5 to 70 C (non-freezing) on compressed air only. AirTAC publishes flow as curves rather than one rated number, so we confirm datasheet figures against your application on request.
| Model | AirTAC GFC600-20 Combination Unit (GFC60020C1WT) |
|---|---|
| Series | GFC600 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT3/4" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC600 | G-series two-unit set, 600 body — sets the port range. |
|---|---|
| 20 | Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR600-20 filter regulator and GL600-20 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC600 · PT3/4" · 5 µm |
|---|---|
| One size down | GFC400 |
| Three-unit equivalent | GC600-20 |
| Build order | Filter regulator first, lubricator last |
Provides 5 um-filtered, regulated and lubricated air to laboratory automation valves and small actuators, protecting them from finer particulate carryover.
Conditions air for an industrial spray-finishing booth's pneumatic agitators and trigger valves, where the 5 um grade supports cleaner air at the gun supply.
Feeds the pick-and-place modules on an electronics assembly panel, with fine 5 um filtration and a visible MPa gauge for line-side pressure checks.
This code differs from the plain GFC60020C1 only in filtration grade: the W selects 5 um elements where the standard unit filters to 40 um, so step up to this code when downstream valves or instruments need finer air. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow for the G-series is published as curves rather than a single rating, so ask us to confirm datasheet sizing before you order.
Quick checklist
The aluminium-alloy bowls on the GFC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR600-20 filter regulator on its own.
We cannot quote a flow number for any G-series unit, including this one, because AirTAC publishes flow as performance curves rather than a single rated figure. Request the datasheet from us and we will confirm the curve data so you can size the 5 um set correctly.
The W in the code selects 5 um filtration instead of the standard 40 um grade; drain, gauge, port and thread decode identically. Both grades are catalogue options on the GFC family, so choose by how clean your downstream components need the air.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.