The AirTAC GFC600-20 Combination Unit (GFC60020MF1T) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/4" ports, a 40 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).
The GFC two-unit set pairs a filter regulator with a lubricator so filtration, pressure regulation and oil-mist lubrication come from one AirTAC order. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. At the 600 size, the filter-section bowl is aluminium alloy.
This is a genuine AirTAC part, for compressed air only, rated to 1.0 MPa (145 psi) inlet and -5 to 70 C (non-freezing), with the regulator adjusting 0.05-0.9 MPa (7-130 psi) as a manual-drain unit. The G series is also offered in 200, 300 and 400 sizes with 5 um elements, automatic or differential-pressure drains, round gauges, and G (BSPP) or NPT threads. Flow figures are published as curves, so we confirm datasheet numbers on request. Order code GFC60020MF1T has NPT ports (the T in the code) for North American pipe fittings.
| Model | AirTAC GFC600-20 Combination Unit (GFC60020MF1T) |
|---|---|
| Series | GFC600 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT3/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC600 | G-series two-unit set, 600 body — sets the port range. |
|---|---|
| 20 | Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR600-20 filter regulator and GL600-20 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC600 · PT3/4" · 40 µm |
|---|---|
| One size down | GFC400 |
| Three-unit equivalent | GC600-20 |
| Build order | Filter regulator first, lubricator last |
A maintenance bay running 3/4-inch impact wrenches and air ratchets gets filtered, regulated and lubricated supply at the wall drop - the 600 size matches the header and the 40 um element suits general tool air.
A stamping press's clutch, counterbalance and part-blower circuits all draw from one preparation point; this set conditions the supply, holds the set pressure on the square gauge and oils the clutch air system.
Palletiser clamps and pushers in a block plant run hard all day on dusty plant air; the 40 um element, NPT3/4 conditioning point and oil-mist feed keep the cylinders working shift after shift.
This is the 600 frame with a 3/4-inch NPT port - the size step to take when 300 or 400 units fall short on your flow curves; always compare candidate sizes on the curves rather than any single rating. The manual drain is right where an operator passes the unit regularly; choose automatic (A) for hard-to-reach spots or the differential-pressure default for standard service. The 40 um element is the standard grade for general plant air; the 5 um (W) version is the finer option. The embedded square MPa gauge keeps the set compact; an external round gauge and psi or bar scales are catalogue choices. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Ask us to confirm sizing against your application before ordering.
Quick checklist
The aluminium-alloy bowls on the GFC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR600-20 filter regulator on its own.
AirTAC does not publish a single rated flow figure for this unit - flow is given as performance curves. Share your line pressure and air demand and we will confirm the correct sizing from the datasheet on request.
The blank grade position in GFC60020MF1T specifies the standard 40 um element, which suits general plant air and protects regulators, valves and cylinders from water and coarse particulate. If you need finer filtration for instruments or spraying, the W-coded 5 um version of the same 600 set is the catalogue alternative.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.