AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC20006F2WT AirTAC F.R.L. Combination, NPT1/8, 5 um

The AirTAC GC20006F2WT AirTAC F.R.L. Combination, NPT1/8, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$71.65 $79.15Save 9% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the GC20006F2WT AirTAC F.R.L. Combination, NPT1/8, 5 um

The GC20006F2WT is an AirTAC GC-series three-unit F.R.L. combination: a separate filter, pressure regulator and lubricator assembled as one air-preparation set. This configuration is the size 200 unit with a NPT1/8 port, the fine 5 um filter element (code W), a differential-pressure drain on the filter bowl, and a fitted square gauge scaled in psi. In use it removes water and particulate down to 5 um, holds a stable downstream pressure adjustable from 0.15-0.9 MPa (20-130 psi), and meters oil mist into the air stream to extend the life of downstream pneumatic components.

This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and options including 40 um or 5 um filtration, automatic, manual or differential-pressure drains, MPa, psi or bar gauge scales, G or NPT threads, and a reverse/check valve. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.

GC20006F2WT AirTAC F.R.L. Combination, NPT1/8, 5 um Technical Specifications

ModelGC20006F2WT AirTAC F.R.L. Combination, NPT1/8, 5 um
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/8" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC20006F2WT AirTAC F.R.L. Combination, NPT1/8, 5 um

GC200G-series F.R.L. combination, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/8" · 5 µm
One size upGC300
Two-unit equivalentGFC200-06
Build orderFilter → regulator → lubricator

Where the GC20006F2WT AirTAC F.R.L. Combination, NPT1/8, 5 um Is Used

factory

Bottling-line capper and filler cylinders

Feeding the air cylinders that drive capping heads and fill nozzles: the 5 um element keeps moisture and fines out of the valve stack, the regulator holds a steady setting shift to shift, and the lubricator keeps the cylinder seals working over long production runs.

precision_manufacturing

Robot weld-cell end-of-arm grippers

Supplying gripper and clamp actuators on a robotic weld cell, where a stable regulated pressure keeps grip force repeatable and the fine 5 um grade protects the small pilot valves mounted on the arm.

conveyor_belt

Packaging-line case sealer and labeler stations

Conditioning the air at the drop for carton sealers and pressure-sensitive labelers: clean, regulated and oil-misted air keeps the staple and taping heads and the label-applicator cylinders running through a full shift without pressure drift.

Is the GC20006F2WT AirTAC F.R.L. Combination, NPT1/8, 5 um the Right Station?

Start with the size and port: the 200 series with its NPT1/8 port suits compact circuits and low-to-moderate air demand, while 300, 400 and 600 step up in port size and flow capacity. Because flow is published as curves rather than a single rated figure, send us your air demand and we will confirm sizing against the datasheet before you order. Then choose the drain type: this unit uses the differential-pressure drain (default); automatic (A) and manual (M) versions exist if your maintenance routine suits them better. The 5 um element (W) is the finer choice for sensitive valves and instruments; the 40 um standard element suits general circuits.

This configuration carries the square gauge scaled in psi; MPa and bar scales, and an external round gauge, are available as options. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. A mounting bracket is included. If you want the functions combined in fewer bodies, the GFC two-unit (filter-regulator plus lubricator) or the GFR filter-regulator alone may fit; ask us to compare.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.

GC20006F2WT AirTAC F.R.L. Combination, NPT1/8, 5 um FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a figure here. Tell us your operating pressure and air demand and we will confirm the sizing from the datasheet on request before you order.

The W in the code GC20006F2WT specifies the optional 5 um element, the finer grade suited to pilot valves, instruments and other sensitive downstream components. The GC series standard element is 40 um for general circuits; if your application does not need fine filtration, ask us for the 40 um variant of the same size.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for GC20006F2WT AirTAC F.R.L. Combination, NPT1/8, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20006F2WT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.