verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC20006LC2T AirTAC F.R.L. Unit, NPT1/8, Low-Pressure

The AirTAC GC20006LC2T AirTAC F.R.L. Unit, NPT1/8, Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$71.65 $79.15Save 9% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the GC20006LC2T AirTAC F.R.L. Unit, NPT1/8, Low-Pressure

The GC20006LC2T is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one complete air-treatment set. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. A round gauge with a psi scale is fitted, and a mounting bracket is included. It treats compressed air in one pass: water and particulate are drained from the filter bowl, downstream pressure is set on the regulator, and oil mist is metered to the air line to lubricate downstream equipment.

This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600 with a choice of port sizes, three thread types (NPT on this code), differential-pressure, automatic or manual drains, 40 um or 5 um (W) filter grades, and gauge scale options. Full rated flow figures are published as curves rather than a single number, so ask us to confirm the datasheet and sizing for your application.

GC20006LC2T AirTAC F.R.L. Unit, NPT1/8, Low-Pressure Technical Specifications

ModelGC20006LC2T AirTAC F.R.L. Unit, NPT1/8, Low-Pressure
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC20006LC2T AirTAC F.R.L. Unit, NPT1/8, Low-Pressure

GC200G-series F.R.L. combination, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/8" · 40 µm
One size upGC300
Two-unit equivalentGFC200-06
Build orderFilter → regulator → lubricator

Where the GC20006LC2T AirTAC F.R.L. Unit, NPT1/8, Low-Pressure Is Used

precision_manufacturing

Compact CNC machine tool air supply

Mounted at the machine inlet on a small-bore NPT1/8 supply line, the unit filters condensed water and swarf-laden particulate from shop air, holds a stable low regulated pressure to the machine's pneumatic circuits, and meters oil mist to spindle and tool-change actuators.

factory

Packaging machinery control air

On a packaging line's carton-forming and sealing station, the combination conditions the air feeding directional valves and small cylinders: the filter drains carry-over moisture, the low-pressure regulator sets the working pressure for delicate sealing jaws, and the lubricator keeps valve spools and cylinder seals running smoothly.

science

Laboratory automation air preparation

Feeding benchtop lab automation and sample-handling pneumatics, the unit supplies clean, pressure-controlled and lubricated air at low regulated settings from a small NPT1/8 line, protecting sensitive grippers and micro-cylinders from moisture, dirt and dry-running.

Is the GC20006LC2T AirTAC F.R.L. Unit, NPT1/8, Low-Pressure the Right Station?

Start with the size and port step: 200 is the smallest GC size, and the NPT1/8 port suits compact supply lines - step up to 300, 400 or 600 where the line and required flow are larger. The drain choice matters in use: this unit has the differential-pressure drain (the default), while automatic (A) and manual (M) drains are orderable variants. Filtration is the 40 um standard grade; specify the W code for 5 um where finer particle removal is needed. The fitted gauge here is the external round type with a psi scale; embedded square gauges with MPa, psi or bar scales are the standard alternative. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Because flow is published as curves rather than a single rated figure, send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.

GC20006LC2T AirTAC F.R.L. Unit, NPT1/8, Low-Pressure FAQ

AirTAC publishes flow for this series as performance curves rather than a single rated number, so we do not quote a rated flow figure. Send us your application details and we will confirm the flow data from the datasheet and check the sizing against your line before you order.

The L in the code marks the low-pressure regulator type, intended for applications where the working pressure must be set below the standard range. The exact adjustment range for the low-pressure type is not published in our current data, so ask us to confirm it from the datasheet for your set pressure. Note this unit is fitted with a round gauge on a psi scale for setting and monitoring.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for GC20006LC2T AirTAC F.R.L. Unit, NPT1/8, Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20006LC2T and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.