verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC20006MLC2TK AirTAC F.R.L. Combination, NPT1/8

The AirTAC GC20006MLC2TK AirTAC F.R.L. Combination, NPT1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$86.58 $94.08Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the GC20006MLC2TK AirTAC F.R.L. Combination, NPT1/8

The GC20006MLC2TK is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one complete air-preparation set. This 200-size unit is configured with NPT 1/8 inch ports, a manual drain on the filter bowl, the standard 40 um filter element, a low-pressure type regulator, an external round gauge reading in psi, a reverse/check valve fitted on the regulator, and a mounting bracket included. In use, the filter removes water and particulate from the compressed air, the regulator holds a steady low-pressure setting downstream, and the lubricator adds a controlled oil mist for air-powered tools and cylinders.

This is a genuine AirTAC part. The GC family is offered in 200, 300, 400 and 600 sizes with port sizes from 1/8 to 1 inch, and with choices of drain type, filter grade, gauge style and scale, thread type and reverse valve. Flow figures are published as curves rather than a single rating, so we confirm the datasheet and sizing for your application on request.

GC20006MLC2TK AirTAC F.R.L. Combination, NPT1/8 Technical Specifications

ModelGC20006MLC2TK AirTAC F.R.L. Combination, NPT1/8
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/8" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC20006MLC2TK AirTAC F.R.L. Combination, NPT1/8

GC200G-series F.R.L. combination, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/8" · 40 µm
One size upGC300
Two-unit equivalentGFC200-06
Build orderFilter → regulator → lubricator

Where the GC20006MLC2TK AirTAC F.R.L. Combination, NPT1/8 Is Used

precision_manufacturing

Pneumatic clamping on an assembly cell

Feeds filtered, regulated and lubricated air to clamp cylinders and pick-and-place actuators on a small assembly fixture, holding a steady low-pressure setting so parts are gripped consistently cycle after cycle.

conveyor_belt

Actuator supply on a bottling conveyor line

Conditions the air feeding pusher and diverting cylinders along a bottling or packaging conveyor, with the lubricator keeping cylinder seals working and the manual drain cleared during routine line checks.

handyman

Workshop air tool station

Sits at the drop point of a maintenance workshop air line, cleaning the supply, holding a low regulated pressure for delicate air tools, and carrying oil mist to impact drivers, ratchets and air ratcheting wrenches.

Is the GC20006MLC2TK AirTAC F.R.L. Combination, NPT1/8 the Right Station?

Start with the port step: this unit is 200 size with NPT 1/8 inch ports, so step up to 300, 400 or 600 if the downstream air demand is larger - match the size to required flow rather than to the pipe alone. The manual drain here means someone opens the bowl drain during checks; if the unit sits where regular draining is awkward, an automatic or differential-pressure drain version is the practical choice. The standard element is 40 um; specify the W option for a 5 um grade if downstream equipment needs finer filtration. The gauge is the external round type reading in psi; embedded square gauges and MPa or bar scales are the other catalogue choices. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Note this is the low-pressure type regulator: it is intended for lower setting ranges, and the exact adjustment range is not published, so ask us to confirm it against your setpoint before ordering. Because flow is published as curves and not a single rated figure, send us your application details and we will confirm sizing before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.

GC20006MLC2TK AirTAC F.R.L. Combination, NPT1/8 FAQ

AirTAC publishes flow for the GC series as characteristic curves, not as a single rated number, so there is no one l/min, SCFM or Cv figure we can honestly quote. Tell us your inlet pressure and the air demand of your equipment, and we will confirm the sizing against the datasheet curves on request before you order.

The M in the code GC20006MLC2TK specifies a manual drain on the filter bowl: collected water is released by hand during checks. If the unit is mounted where regular access is difficult, the GC family also offers automatic and differential-pressure drain versions, so ask us to quote the drain type that suits the installation.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for GC20006MLC2TK AirTAC F.R.L. Combination, NPT1/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20006MLC2TK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.