AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC20008LC2TK AirTAC F.R.L. Combination, NPT1/4, Low-Pressure

The AirTAC GC20008LC2TK AirTAC F.R.L. Combination, NPT1/4, Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$86.58 $94.08Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the GC20008LC2TK AirTAC F.R.L. Combination, NPT1/4, Low-Pressure

The GC20008LC2TK is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one 200-size unit with a NPT1/4 (1/4 in) port. The filter element is the standard 40 um grade with a differential-pressure drain, the regulator is the low-pressure type, and this configuration carries a round gauge scaled in psi plus a reverse/check valve. A mounting bracket is included. Medium is compressed air; maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600 with a choice of three thread types (NPT on this code), drain type, filter grade (40 um standard, 5 um optional), gauge style and scale, and check-valve option. Flow is published as curves rather than a single rating, so we confirm flow and datasheet figures on request before you order.

GC20008LC2TK AirTAC F.R.L. Combination, NPT1/4, Low-Pressure Technical Specifications

ModelGC20008LC2TK AirTAC F.R.L. Combination, NPT1/4, Low-Pressure
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC20008LC2TK AirTAC F.R.L. Combination, NPT1/4, Low-Pressure

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 40 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the GC20008LC2TK AirTAC F.R.L. Combination, NPT1/4, Low-Pressure Is Used

precision_manufacturing

Pneumatic press and clamping station

Feeds filtered, regulated and lubricated air to a clamping or light-press circuit on a machining fixture, where the low-pressure regulator type suits circuits set below standard ranges and the check valve holds the clamp position if supply is lost.

conveyor_belt

Packaging conveyor air supply

A single NPT1/4 supply point for cylinders and air jets along a packaging or cartoning conveyor: 40 um filtration removes water and particulate, and the lubricator mists oil for cylinder and valve longevity.

factory

Assembly-cell drop supply

A bench- or machine-mounted air drop in an assembly cell, where the included bracket fixes the three-unit set to the frame and the psi-scaled round gauge lets operators read and set line pressure directly.

Is the GC20008LC2TK AirTAC F.R.L. Combination, NPT1/4, Low-Pressure the Right Station?

Start with the size and port: 200 is the smallest GC frame, and the port step (1/8 in through 1 in across the family) should be chosen against the air demand of the circuit - ask us to confirm sizing against the published flow curves, since no single rated flow figure is published. Then set the options that matter on this code: the low-pressure regulator type for circuits running below standard regulator ranges (exact range not published - confirm with us), the 40 um standard element versus the 5 um W option, drain type (differential-pressure here, with automatic and manual available), gauge scale (MPa, psi or bar), and thread (NPT on this code). The fitted reverse/check valve holds downstream pressure when the upstream supply is removed.

Because flow is published as curves and not a single rating, we confirm the datasheet and sizing against your application on request before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

GC20008LC2TK AirTAC F.R.L. Combination, NPT1/4, Low-Pressure FAQ

AirTAC publishes flow for this family as curves, not as a single rated figure, so we do not quote a number here. Contact us with your air demand and we will confirm the flow data from the datasheet and check the 200 size and NPT1/4 port against your application before you order.

L is the low-pressure regulator type, for circuits running below standard regulator settings (the exact range is not published - we confirm it on request). K means a reverse/check valve is fitted, holding downstream pressure if the supply is removed. This code carries a round gauge scaled in psi; the embedded square gauge is standard and external round gauges with MPa, psi or bar scales are orderable options.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for GC20008LC2TK AirTAC F.R.L. Combination, NPT1/4, Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC20008LC2TK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.