verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30008AC2TK AirTAC F.R.L. Combination, NPT1/4

The AirTAC GC30008AC2TK AirTAC F.R.L. Combination, NPT1/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$136.04 $143.54Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-08 drain, gauge and thread option on one page All GC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the GC30008AC2TK AirTAC F.R.L. Combination, NPT1/4

The GC30008AC2TK is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator built as one set. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi), a reverse/check valve (code K) is included, and a mounting bracket comes with the set. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. The filter and lubricator bowls on this size are PC (polycarbonate).

This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600 with ports stepping from 1/8 in up to 1 in, and with options including manual or differential-pressure drains, a 5 um filter element (code W), square embedded gauges with MPa, psi or bar scales, G (BSPP) and NPT threads, and low-pressure regulator types. Flow is published as curves rather than a single rated figure, so we confirm flow and datasheet figures on request.

GC30008AC2TK AirTAC F.R.L. Combination, NPT1/4 Technical Specifications

ModelGC30008AC2TK AirTAC F.R.L. Combination, NPT1/4
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30008AC2TK AirTAC F.R.L. Combination, NPT1/4

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the GC30008AC2TK AirTAC F.R.L. Combination, NPT1/4 Is Used

factory

Automotive assembly line air drops

At point-of-use drops feeding air tools and cylinders on a final assembly line, this three-unit set filters water and particulate from the supply, holds a steady regulated pressure for consistent tool torque, and carries oil mist to lubricate impact wrenches and ratchets through the shift.

conveyor_belt

Packaging and bottling line pneumatics

On a bottling or cartoning conveyor, diverters, pushers and stop gates run on compressed air around the clock. This set conditions the line supply in one pass, with the automatic drain handling condensate so the pneumatics stay dry, regulated and lubricated without an operator visiting the bowl.

precision_manufacturing

CNC machine tool air supply

CNC machining cells use compressed air for tool-clamp cylinders, chip-blast nozzles and air springs. Feeding the machine through this F.R.L. set removes water and swarf-carrying particles, keeps clamp pressure stable within the regulator range, and lubricates the actuated circuits, with the check valve holding the line during momentary supply dips.

Is the GC30008AC2TK AirTAC F.R.L. Combination, NPT1/4 the Right Station?

Size and port: this size 300 set is ported NPT1/4; the G-series steps through 200/300/400/600 with larger ports for larger air demand. Drain type: this unit has an automatic drain (code A); manual and differential-pressure drains are the other catalogue choices. Filter grade: 40 um is standard here, with 5 um (code W) available where finer filtration is needed. Gauge: this set carries a round gauge scaled in psi; embedded square gauges and MPa or bar scales are alternatives. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

GC30008AC2TK AirTAC F.R.L. Combination, NPT1/4 FAQ

AirTAC publishes flow for the GC300 as curves, not as a single rated figure, so we do not quote a number here. Send us your air consumption and working pressure and we will confirm from the datasheet whether this NPT1/4 set is correctly sized, or whether a larger size in the family is the better match.

The A is the drain code: this filter is fitted with an automatic drain, which expels collected condensate on its own instead of waiting for someone to open the bowl. Manual and differential-pressure drains are the other catalogue choices; automatic is the usual pick for unmanned or hard-to-reach installations.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for GC30008AC2TK AirTAC F.R.L. Combination, NPT1/4

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30008AC2TK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.