The AirTAC GC30008ALF2WTK AirTAC F.R.L. Combination, NPT1/4, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC30008ALF2WTK is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one set. This configuration is built around a NPT1/4 (1/4 in) port in the 300 size. The filter element is the fine 5 um grade (the standard grade is 40 um) and the bowl drains automatically, so collected water is expelled without manual attention. The regulator is the low-pressure type, and a square gauge scaled in psi is fitted so the set-point can be read directly. A reverse/check valve is fitted, and a mounting bracket is included. The filter and lubricator bowls are polycarbonate (PC); only the 600 size uses aluminium alloy bowls.
This is a genuine AirTAC part. The GC family is offered in sizes 200, 300, 400 and 600 with matching port sizes, and options include thread type (NPT on this code), drain type, filter grade, gauge scale and reverse/check valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GC30008ALF2WTK AirTAC F.R.L. Combination, NPT1/4, 5 um |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · PT1/4" · 5 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-08 |
| Build order | Filter → regulator → lubricator |
Feeding a bank of pneumatic screwdrivers and clamps on an assembly line: the filter removes water and fine particulate, the low-pressure regulator holds the circuit set-point, and the lubricator mists oil to the tools.
Supplying the air cylinders that index and divert product on a packaging conveyor, where clean, lubricated air at a stable low pressure keeps the actuators cycling through the shift.
Mounted on the bracket at a CNC machine tool's pneumatic panel: 5 um filtration ahead of the regulator and lubricator protects valves and cylinders fed from the same NPT1/4 supply.
Size and port step up together: 200/300/400/600, with this unit at 300 and NPT1/4. Choose the size whose flow curve covers your demand - we can check the curve against your application on request. Drain choice matters: automatic drain (this unit) suits unattended duty, while manual and differential-pressure drains are also available in the family. Filter grade is 5 um here (code W) versus the 40 um standard - pick 5 um where downstream equipment needs finer water and particulate removal. The regulator is the low-pressure type; gauge scale options are MPa, psi (fitted here) or bar. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. A mounting bracket is included, and the reverse/check valve (code K) is fitted on this unit.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.
AirTAC publishes flow for this family as curves, not as a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the datasheet flow figures for the GC300 size and NPT1/4 port on request, so you can size the unit correctly before ordering.
The W code in GC30008ALF2WTK selects the 5 um element instead of the 40 um standard, for finer removal of water and particulate ahead of the regulator and lubricator. The A code selects the automatic drain, which expels collected condensate on its own instead of waiting for a manual drain. Both are standard catalogue options across the GC family.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.