The AirTAC GC30008LF2WT AirTAC F.R.L. Combination, NPT1/4, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC30008LF2WT is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator set up as one treatment train. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The regulator is the low-pressure type, and the fitted square gauge reads in psi so operators can set and monitor line pressure directly. The filter bowl drains by differential pressure, and the polycarbonate bowls let you see accumulated water and oil at a glance. A mounting bracket is included.
This is a genuine AirTAC part. The GC family is offered in sizes 200, 300, 400 and 600 with matching port sizes, and with options across drain type, filter grade, gauge scale and thread form (NPT on this code). Because AirTAC publishes flow for this family as curves rather than a single rated figure, we confirm the datasheet and flow figures for your application on request before you order.
| Model | GC30008LF2WT AirTAC F.R.L. Combination, NPT1/4, 5 um |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · PT1/4" · 5 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-08 |
| Build order | Filter → regulator → lubricator |
Feeding impact wrenches and pneumatic screwdrivers at a final-assembly station: the filter strips water and 5 um-scale particulate, the low-pressure regulator holds a steady setting read on the psi gauge, and the lubricator carries oil mist to keep the tools running through a full shift.
Supplying the air cylinders that raise, clamp and push cartons on a packaging conveyor. Clean, regulated and lubricated air keeps the valve spools and cylinder seals working consistently, while the differential-pressure drain and visible PC bowls make water build-up easy to spot during line checks.
Feeding framing nailers and staplers at a workshop bench or small production cell. The 5 um element protects the tool trigger valves from moisture and fine debris, the regulator sets the driving pressure on the psi gauge, and the lubricator mists oil into the air so the drivers last longer between services.
Start with the port and size step: this unit is size 300 with a 1/4 in NPT port, and the GC family steps up through sizes 200, 300, 400 and 600 as your flow demand grows - match the step to the air consumption of the downstream cylinders and tools rather than to the pipe alone. Filter grade is a real choice here: the standard element is 40 um, while this unit carries the W-coded 5 um element for finer water and particulate removal ahead of sensitive valves and actuators. Drain type is also selectable across the family: differential-pressure (as fitted here), automatic, or manual. Gauge scale can be ordered in MPa, psi or bar, and thread can be three thread types (NPT on this code). Note that this is the low-pressure regulator type; its exact adjustment range is not published in the material we hold, so ask us to confirm it against your set pressure. Above all, treat sizing honestly: flow is published as curves, not a single rating, so send us your application details and we will confirm the right size before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.
AirTAC publishes flow for the GC family as performance curves rather than a single rated figure, so we do not quote one number here. Tell us your application - the downstream cylinders or tools, working pressure and duty - and we will confirm the flow and datasheet figures for this exact unit on request before you order.
GC is the three-unit F.R.L. combination family (separate filter, regulator and lubricator); 300 is the size series; 08 is the 1/4 in NPT port; L is the low-pressure regulator type; F is the fitted square gauge with scale 2, reading in psi; and W is the 5 um filter element instead of the standard 40 um. The drain is the differential-pressure type, and a mounting bracket is included.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.