verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30008LF2WT AirTAC F.R.L. Combination, NPT1/4, 5 um

The AirTAC GC30008LF2WT AirTAC F.R.L. Combination, NPT1/4, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$107.41 $114.91Save 6% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-08 drain, gauge and thread option on one page All GC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the GC30008LF2WT AirTAC F.R.L. Combination, NPT1/4, 5 um

The GC30008LF2WT is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator set up as one treatment train. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The regulator is the low-pressure type, and the fitted square gauge reads in psi so operators can set and monitor line pressure directly. The filter bowl drains by differential pressure, and the polycarbonate bowls let you see accumulated water and oil at a glance. A mounting bracket is included.

This is a genuine AirTAC part. The GC family is offered in sizes 200, 300, 400 and 600 with matching port sizes, and with options across drain type, filter grade, gauge scale and thread form (NPT on this code). Because AirTAC publishes flow for this family as curves rather than a single rated figure, we confirm the datasheet and flow figures for your application on request before you order.

GC30008LF2WT AirTAC F.R.L. Combination, NPT1/4, 5 um Technical Specifications

ModelGC30008LF2WT AirTAC F.R.L. Combination, NPT1/4, 5 um
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30008LF2WT AirTAC F.R.L. Combination, NPT1/4, 5 um

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the GC30008LF2WT AirTAC F.R.L. Combination, NPT1/4, 5 um Is Used

factory

Automotive assembly line air tools

Feeding impact wrenches and pneumatic screwdrivers at a final-assembly station: the filter strips water and 5 um-scale particulate, the low-pressure regulator holds a steady setting read on the psi gauge, and the lubricator carries oil mist to keep the tools running through a full shift.

conveyor_belt

Carton-sealing conveyor cylinders

Supplying the air cylinders that raise, clamp and push cartons on a packaging conveyor. Clean, regulated and lubricated air keeps the valve spools and cylinder seals working consistently, while the differential-pressure drain and visible PC bowls make water build-up easy to spot during line checks.

handyman

Woodshop pneumatic nailers and staplers

Feeding framing nailers and staplers at a workshop bench or small production cell. The 5 um element protects the tool trigger valves from moisture and fine debris, the regulator sets the driving pressure on the psi gauge, and the lubricator mists oil into the air so the drivers last longer between services.

Is the GC30008LF2WT AirTAC F.R.L. Combination, NPT1/4, 5 um the Right Station?

Start with the port and size step: this unit is size 300 with a 1/4 in NPT port, and the GC family steps up through sizes 200, 300, 400 and 600 as your flow demand grows - match the step to the air consumption of the downstream cylinders and tools rather than to the pipe alone. Filter grade is a real choice here: the standard element is 40 um, while this unit carries the W-coded 5 um element for finer water and particulate removal ahead of sensitive valves and actuators. Drain type is also selectable across the family: differential-pressure (as fitted here), automatic, or manual. Gauge scale can be ordered in MPa, psi or bar, and thread can be three thread types (NPT on this code). Note that this is the low-pressure regulator type; its exact adjustment range is not published in the material we hold, so ask us to confirm it against your set pressure. Above all, treat sizing honestly: flow is published as curves, not a single rating, so send us your application details and we will confirm the right size before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

GC30008LF2WT AirTAC F.R.L. Combination, NPT1/4, 5 um FAQ

AirTAC publishes flow for the GC family as performance curves rather than a single rated figure, so we do not quote one number here. Tell us your application - the downstream cylinders or tools, working pressure and duty - and we will confirm the flow and datasheet figures for this exact unit on request before you order.

GC is the three-unit F.R.L. combination family (separate filter, regulator and lubricator); 300 is the size series; 08 is the 1/4 in NPT port; L is the low-pressure regulator type; F is the fitted square gauge with scale 2, reading in psi; and W is the 5 um filter element instead of the standard 40 um. The drain is the differential-pressure type, and a mounting bracket is included.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for GC30008LF2WT AirTAC F.R.L. Combination, NPT1/4, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC30008LF2WT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.