The AirTAC GC40015ALF2WTK AirTAC F.R.L. Combination, NPT1/2, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC40015ALF2WTK is a three-piece F.R.L. combination that filters, regulates and lubricates compressed air from a single assembled set: a separate filter, a separate pressure regulator and a separate oil-mist lubricator. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. The polycarbonate bowls suit the -5 to 70 C (non-freezing) operating range, and a mounting bracket is included.
This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with a choice of ports, drain types (differential-pressure, automatic or manual), filter grades (40 um standard, 5 um optional), gauge styles and scales (MPa, psi or bar), and reverse/check valve options. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application on request.
| Model | GC40015ALF2WTK AirTAC F.R.L. Combination, NPT1/2, 5 um |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · PT1/2" · 5 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-15 |
| Build order | Filter → regulator → lubricator |
Feeds spray guns and air-assisted applicators on a paint line, where the 5 um element removes water and fine particulate, the regulator holds a steady low setting and the lubricator mists oil to the gun trigger and needle packing.
Supplies the cylinders, grippers and vacuum generators on a cartoning or case-packing conveyor, keeping the air clean, the pressure stable across machine cycles and the seals lubricated through long production runs.
Conditions the air to looms and spinning-frame jets, where the automatic drain clears condensate continuously, the low-pressure regulator suits sensitive jet settings and the oil mist protects moving pneumatic parts.
Step up or down through the 200/300/400/600 size ladder to match the port and flow your line needs; this unit sits at 400 size with a NPT1/2 port. Where a bowl exists, choose the drain: differential-pressure (default), automatic for unattended draining, or manual where you drain on a schedule. Choose the 40 um standard element for general protection or the 5 um element (as fitted here) for finer particulate removal, and pick the gauge scale - MPa, psi or bar - to suit your plant standard. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. a bracket is included, and a reverse/check valve can be fitted as here.
Flow for the GC series is published as curves, not as a single rated number, so we do not quote a rated flow figure. Send us your application details and we will confirm the sizing against the datasheet curves before you order. The exact regulation range of the low-pressure type is likewise confirmed on request.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Tell us your application and required flow and we will confirm the sizing against the datasheet curves on request before you order.
The A in the code sets the automatic drain, which expels collected condensate from the filter bowl without manual attention - useful on unattended lines. The W sets the 5 um filter element instead of the 40 um standard, for finer particulate removal. The L marks the low-pressure type regulator, the F2 the embedded square gauge with psi scale, and the K the fitted reverse/check valve.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.