AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC40015MC2WTK AirTAC F.R.L. Combination, NPT1/2, 5 um

The AirTAC GC40015MC2WTK AirTAC F.R.L. Combination, NPT1/2, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$170.15 $177.65Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the GC40015MC2WTK AirTAC F.R.L. Combination, NPT1/2, 5 um

The GC40015MC2WTK is a three-piece AirTAC F.R.L. combination: a filter, a pressure regulator and an oil-mist lubricator, each in its own body and joined as one air-preparation set for 1/2 in (NPT1/2) pipework. This configuration carries a 5 um filter element (code W) with a manual drain on the filter bowl, a standard regulator adjustable from 0.05 to 0.9 MPa (7-130 psi), a fitted round pressure gauge reading in psi, a reverse/check valve on the regulator, and a mounting bracket. The polycarbonate bowls suit non-freezing compressed air from -5 to 70 C, with a maximum inlet pressure of 1.0 MPa (145 psi).

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600, with port options from 1/8 to 1 in, three thread types (NPT on this code), automatic, manual or differential-pressure drains, 40 um or 5 um filtration, and gauge scales in MPa, psi or bar. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.

GC40015MC2WTK AirTAC F.R.L. Combination, NPT1/2, 5 um Technical Specifications

ModelGC40015MC2WTK AirTAC F.R.L. Combination, NPT1/2, 5 um
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (NPT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC40015MC2WTK AirTAC F.R.L. Combination, NPT1/2, 5 um

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the GC40015MC2WTK AirTAC F.R.L. Combination, NPT1/2, 5 um Is Used

factory

Automotive assembly line air drops

Feeding impact wrenches, nutrunners and air ratchets at assembly stations, where the 5 um element protects tools from fine particulate, the regulator holds a steady working pressure and the lubricator mists oil into the tool air supply.

conveyor_belt

Packaging and cartoning machine supply

Preparing air for conveyor diverters, case erectors and packaging cylinders on a production line, with the reverse/check valve helping hold the downstream pressure setting and the manual drain bled during scheduled line cleaning.

handyman

Machine shop pneumatic workbench

A point-of-use set at a maintenance bench or jig station, supplying spray guns, air clamps and small cylinders from a shop compressor, with the psi round gauge giving a direct local reading of the set pressure.

Is the GC40015MC2WTK AirTAC F.R.L. Combination, NPT1/2, 5 um the Right Station?

Start with the port size: this 400-size unit is supplied with NPT1/2 connections, and the GC series steps through sizes 200 to 600 as port and flow capacity rise. Choose the drain to match maintenance access: this unit has a manual drain, which needs periodic bleeding by hand; automatic and differential-pressure drains are available on other codes. Filtration here is the finer 5 um element (code W) instead of the 40 um standard, which suits downstream equipment that is sensitive to finer particulate. The fitted round gauge reads in psi; MPa and bar scales are offered on other codes. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Because flow for the GC series is published as curves and not as a single rated number, send us your application details and we will confirm the sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

GC40015MC2WTK AirTAC F.R.L. Combination, NPT1/2, 5 um FAQ

AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote a l/min or SCFM number. Send us your application details and we will confirm the datasheet flow curves and sizing for this 400-size, NPT1/2 unit before you order.

The M in the code selects a manual drain on the filter bowl: collected water and contaminant are released by hand, so the bowl needs periodic bleeding as part of routine maintenance. If you prefer unattended drainage, GC codes with automatic or differential-pressure drains are available in the same size range.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for GC40015MC2WTK AirTAC F.R.L. Combination, NPT1/2, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.