verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC40015MLC2TK AirTAC F.R.L. 1/2 in Low-Pressure Unit

The AirTAC GC40015MLC2TK AirTAC F.R.L. 1/2 in Low-Pressure Unit is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$170.15 $177.65Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the GC40015MLC2TK AirTAC F.R.L. 1/2 in Low-Pressure Unit

The AirTAC GC40015MLC2TK is a three-piece F.R.L. combination that conditions compressed air in one assembly: a filter removes water and particulate, a low-pressure regulator holds the downstream set point, and a lubricator adds oil mist for downstream air tools and cylinders. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

This is a genuine AirTAC part. The GC series is available in 200, 300, 400 and 600 sizes with a choice of ports, threads (NPT on this code), drains, filter grades and gauge scales, so a configuration can be matched to most plant air drops. Rated flow is published as curves rather than a single figure, so ask us to confirm sizing or any datasheet figure for your application before ordering.

GC40015MLC2TK AirTAC F.R.L. 1/2 in Low-Pressure Unit Technical Specifications

ModelGC40015MLC2TK AirTAC F.R.L. 1/2 in Low-Pressure Unit
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC40015MLC2TK AirTAC F.R.L. 1/2 in Low-Pressure Unit

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the GC40015MLC2TK AirTAC F.R.L. 1/2 in Low-Pressure Unit Is Used

factory

Plant air drop for assembly cells

A three-unit F.R.L. at the point of use on a factory air header: water and debris are dropped out, pressure is held at the low set point the cell runs at, and tool oil mist is supplied to the hand tools and actuators fed from that drop.

conveyor_belt

Packaging and conveyor actuation lines

Feeding pneumatic cylinders and stop-gates on a packaging or conveyor line, where the filter keeps moisture out of the valves, the low-pressure regulator matches the actuation circuit's set point, and the lubricator extends cylinder and valve service life.

engineering

Maintenance-shop air service panels

A wall- or bracket-mounted conditioning point in a maintenance shop: the 1/2 in NPT connection serves impact wrenches and air ratchets, the manual drain is bled at shift checks, and the psi gauge lets technicians set and verify line pressure at a glance.

Is the GC40015MLC2TK AirTAC F.R.L. 1/2 in Low-Pressure Unit the Right Station?

Start with the port and size: this unit is 400 size with a 1/2 in NPT port, and the larger the size the larger the port and the greater the flow capacity. The filter bowl here drains manually, which suits installations where an operator can bleed accumulated water on a routine; automatic or differential-pressure drains are available if no one will be at the unit. The 40 um element is the standard grade; a 5 um element (code W) is offered where finer filtration is wanted. The low-pressure regulator type is chosen for circuits that run below the standard regulator's normal band - its exact adjustment range is not published, so confirm it with us. The round gauge reads in psi; MPa and bar scales are alternatives. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

Because flow is published as curves and not a single rated number, send us your line size and demand and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

GC40015MLC2TK AirTAC F.R.L. 1/2 in Low-Pressure Unit FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a number here. Tell us your line size and air demand and we will confirm the sizing against the datasheet on request before you order.

The M in the code selects a manual drain: an operator opens the filter bowl drain to remove accumulated water, which suits attended installations; automatic and differential-pressure drains are available as alternatives. The L selects the low-pressure regulator type, intended for circuits running below the standard band; its exact adjustment range is not published, so confirm the range with us for your set point.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for GC40015MLC2TK AirTAC F.R.L. 1/2 in Low-Pressure Unit

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GC40015MLC2TK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.