The AirTAC GFR300C10AJC2WGK AirTAC Filter Regulator G3/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR300C10AJC2WGK is an AirTAC GFR300 filter regulator: water and particulate filtration plus pressure regulation combined in a single body, sized for a G3/8 (3/8 in) port with G (BSPP) thread. This configuration carries the 5 um filter element (the finer of the two grades), an automatic drain that ejects collected condensate without manual attention, an external round gauge reading in psi, and a built-in reverse/check valve that holds downstream pressure if the supply drops. Maximum inlet pressure is 1.0 MPa (145 psi), the standard regulator adjusts from 0.15 to 0.9 MPa (20-130 psi), and the operating temperature range is -5 to 70 C (non-freezing). The bowl on this size is polycarbonate (PC), and the unit is supplied without a mounting bracket.
This is a genuine AirTAC part from the GFR series, which spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drains, 40 um or 5 um filtration, embedded square or external round gauges with MPa, psi or bar scales, and PT, G or NPT threads. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.
| Model | GFR300C10AJC2WGK AirTAC Filter Regulator G3/8, 5 um |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C1 (two-unit set) |
Filtering and regulating the shop-air feed to a CNC machine's tool-clamp and chip-door cylinders, where the 5 um element and psi-scaled gauge match the machine builder's inlet specification.
Conditioning air ahead of the pick-and-place and sealing cylinders on a carton packaging line, with the built-in check valve holding the set pressure through brief supply dips.
Regulating supply to pneumatic quarter-turn valve actuators on a water-treatment skid, where the automatic drain handles condensate on a line that stays pressurised around the clock.
Pick the size step (200/300/400/600) and port to match the flow your line needs - here 3/8 in on the 300 body. Drain type is a real decision: differential-pressure (the default) drains only while air flows, automatic drains continuously, and manual needs periodic attention; this unit is automatic. Filtration is 5 um on this model against the 40 um standard - choose 5 um where downstream valves and instruments are sensitive. Gauges are the embedded square type or an external round gauge scaled in MPa, psi or bar; this one is a round psi gauge. Thread is G (BSPP) here, with PT as the standard and G/NPT as order options, and brackets are optional (this unit has none). Because flow is published as curves rather than a single rating, send us your application and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR300 flow as curves, not as a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and sizing from the datasheet on request.
The W code specifies the 5 um element against the 40 um standard, for finer protection of downstream valves and instruments. The A code specifies an automatic drain, which ejects collected condensate without manual attention - useful on lines that stay pressurised. The K code adds a reverse/check valve that holds downstream pressure if supply is lost. This standard regulator adjusts 0.15-0.9 MPa (20-130 psi) with a 1.0 MPa (145 psi) maximum inlet.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.