The AirTAC GFR300C10AJF2WG AirTAC Filter Regulator G3/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR300C10AJF2WG is an AirTAC GFR300 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration has a G3/8 (BSPP) port, a 5 um filter element (code W, against the 40 um standard), an automatic drain, a standard regulator with a 0.15-0.9 MPa (20-130 psi) adjustment range, and an embedded square gauge scaled in psi. No mounting bracket is included and no reverse/check valve is fitted. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family is offered in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, a choice of differential-pressure, automatic or manual drain, 40 um or 5 um filtration, gauge scale options, and PT, G or NPT threads. On size 300 the bowl is polycarbonate (size 600 uses aluminium alloy). Flow is published as curves rather than a single rated figure, so ask us to confirm flow and other datasheet figures for your application.
| Model | GFR300C10AJF2WG AirTAC Filter Regulator G3/8, 5 um |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C1 (two-unit set) |
Filtered, regulated air feeding pneumatic clamps and tool-change cylinders on a machining centre, with the 5 um element protecting fine control valves downstream.
Steady supply pressure for positioners and pilot valves on a process skid, with the automatic drain clearing condensate and the psi gauge giving a local setpoint check.
Regulated air for carton-sealing and case-packing cylinders along a packaging conveyor, where operators read the setpoint directly off the square psi gauge.
Pick the size step (200/300/400/600) and port against the flow your line needs; this model sits at size 300 with a 3/8 inch G-thread port. The real decodable choices are drain type (differential-pressure standard, automatic, or manual - note the manual-drain version widens the regulation range down to 0.05 MPa), filter grade (40 um standard, 5 um with code W, as fitted here), gauge scale (MPa, psi or bar), thread (PT standard, G or NPT to order) and the optional bracket. Flow is published as curves, not a single rating, so send us your application conditions and we will confirm sizing from the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR300 flow as curves rather than a single rated figure, so we do not quote a number here. Send us your application conditions and we will confirm the flow and other datasheet figures on request.
The 40 um element is the standard grade for general plant air. The 5 um W element fitted to this model is the finer catalogue option for downstream equipment that is sensitive to smaller particles; both grades are available across the GFR range.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.