verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

GFR300C10ALNT AirTAC Filter Regulator, NPT3/8, Low-Pressure

The AirTAC GFR300C10ALNT AirTAC Filter Regulator, NPT3/8, Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$52.54 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR300C10ALNT AirTAC Filter Regulator, NPT3/8, Low-Pressure

The AirTAC GFR300C10ALNT combines water and particulate filtration with pressure regulation in a single size-300 body, so one component cleans the air and sets the downstream pressure on a 3/8 in NPT line. This configuration carries a 40 um filter element, an automatic drain that expels collected condensate without manual attention, and the low-pressure regulator type. No gauge is fitted on this variant, and a mounting bracket is included. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with a choice of ports, PT (standard), G or NPT threads, manual, automatic or differential-pressure drains, a 5 um element option (code W), and gauge or no-gauge variants. Flow figures are published as curves rather than a single rating; ask us and we will confirm the datasheet figures for your application on request.

GFR300C10ALNT AirTAC Filter Regulator, NPT3/8, Low-Pressure Technical Specifications

ModelGFR300C10ALNT AirTAC Filter Regulator, NPT3/8, Low-Pressure
SeriesGFR300 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR300C10ALNT AirTAC Filter Regulator, NPT3/8, Low-Pressure

GFR300G-series filter regulator, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · See datasheet · 40 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-C1 (two-unit set)

Where the GFR300C10ALNT AirTAC Filter Regulator, NPT3/8, Low-Pressure Is Used

precision_manufacturing

Pneumatic press drop at a fabrication shop

Mounted at the drop feeding a bench pneumatic press, the unit strips water and chips from the shop air line and holds a steady regulated supply to the press cylinder, with the automatic drain handling condensate between shifts.

conveyor_belt

Carton-sealing station on a packaging conveyor

Installed ahead of the air cylinders that drive a carton taping and folding station, it cleans the compressed air and regulates the supply to the sealing heads, while the automatic drain keeps moisture out of the valves on a line that runs unattended.

settings_input_component

Air supply to a machine tool's clamping circuit

Fitted on the supply to the fixture-clamping circuit of a CNC machine cell, it removes particulate and water before the solenoid valves and regulates the pressure delivered to the clamps, with the included bracket simplifying cabinet or frame mounting.

Is the GFR300C10ALNT AirTAC Filter Regulator, NPT3/8, Low-Pressure the Right Unit?

Start with the size and port: this unit is size 300 with a 3/8 in NPT port, one step up from the 1/4 in size-200 units, so step up if your line demands more air. The automatic drain on this model suits points where nobody regularly walks past to bleed the bowl; choose manual drain where visits are routine and you want zero bleed, or differential-pressure drain as the catalogue default. The 40 um element is the standard grade; specify the W code for the 5 um element if downstream equipment needs finer filtration. This is the low-pressure regulator type; its exact regulation range is not published in the material we hold, so confirm it with us before ordering if your setpoint is critical. No gauge is fitted, so plan for external pressure indication if you need a setpoint reading. PT is the standard thread; G and NPT are order options, and this unit is supplied with a mounting bracket.

One honest note on sizing: AirTAC publishes flow as curves, not a single rated figure, so we cannot quote you a flow number here. Send us your application details and we will confirm the sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR300C10ALNT AirTAC Filter Regulator, NPT3/8, Low-Pressure FAQ

AirTAC publishes flow for this family as curves rather than a single rated figure, so there is no one flow number we can honestly quote. Tell us your line pressure and the air demand of your equipment, and we will confirm the sizing against the datasheet on request.

The N in the code means no gauge is fitted, so add external pressure indication if you need to read the setpoint. The L in the code marks the low-pressure regulator type; its exact regulation range is not published in our current material, so confirm the range with us before ordering if your application runs at a low setpoint.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR300C10ALNT AirTAC Filter Regulator, NPT3/8, Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR300C10ALNT and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.