The AirTAC GFR300C10JNWT AirTAC Filter Regulator 3/8 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR300C10JNWT is a filter regulator: water and particulate removal plus downstream pressure regulation combined in one body. This size 300 unit carries a 3/8 in NPT port, a 5 um filter element (the finer of the two catalogue grades), and a differential-pressure drain that bleeds collected condensate automatically whenever the pressure differential across the element is high enough. The regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi), maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). No pressure gauge is fitted and no mounting bracket is included with this configuration.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in up to 1 in, and is orderable with manual or automatic drains, a 40 um standard element, embedded square or external round gauges, and PT, G or NPT threads. Flow is published as curves rather than a single rated figure, so ask us to confirm the sizing and datasheet figures for your application before ordering.
| Model | GFR300C10JNWT AirTAC Filter Regulator 3/8 in NPT |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C1 (two-unit set) |
Feeds filtered, regulated air to the tool-clamp and chip-clearing circuits of a CNC machining centre, where the 5 um element helps keep moisture and fine particles out of clamping valves.
Prepares the air feeding carton-forming and case-sealing cylinders on a packaging line, holding a steady set pressure so sealing strokes stay consistent through the shift.
Conditions the supply to pneumatic grippers and pick-and-place actuators on a robot cell, combining water removal and pressure setting in a single panel position.
Choose the size and port step against the air consumption of the tools or actuators downstream: this unit is size 300 with a 3/8 in NPT port. The 5 um element fitted here suits applications that need finer particulate control than the 40 um standard grade; the coarser element is available in the same body if your line does not require it. The differential-pressure drain fitted here is the default and needs no daily attention, but manual-drain versions (which widen the regulation range to 0.05-0.9 MPa) and automatic-drain versions can be ordered instead. This configuration has no gauge and no bracket; a square or round gauge in MPa, psi or bar scale, and a mounting bracket, are orderable options, as are G (BSPP) and PT threads in place of NPT. Because flow is published as curves and not as a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the flow and sizing from the datasheet on request before you order.
This configuration is ordered without a gauge (code N). The GFR300 family accepts an embedded square gauge or an external round gauge in MPa, psi or bar scale as an order option, so specify the gauge and scale you want when ordering if you need a local pressure indication.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.