The AirTAC GFR300C10LJF1WTK AirTAC Filter Regulator NPT3/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR300C10LJF1WTK is an AirTAC GFR300 filter regulator: one body that removes water and particulate from compressed air and regulates downstream pressure. This configuration has NPT3/8 ports, a 5 um filter element (code W), a metal bowl with differential-pressure drain, an embedded square gauge scaled in MPa, a fitted reverse (check) valve, and no mounting bracket. It is the low-pressure (L) type, intended for circuits that run at reduced regulated pressures; the exact adjustment range for this type is not published, so confirm it with us.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and options including manual or automatic drains, the 5 um element, gauge scale choices, G (BSPP) or NPT threads, and check valves. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm sizing and any datasheet figure for your application.
| Model | GFR300C10LJF1WTK AirTAC Filter Regulator NPT3/8 |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C1 (two-unit set) |
Placed ahead of clamping cylinders on a CNC fixture circuit, it strips water and fine particles from the shop air and delivers a reduced, regulated supply pressure to the clamps.
Conditioning the supply to directional control valves on a carton-sealing or wrapping line, protecting valve spools from moisture and debris while regulating pressure to the manifold.
Feeding pneumatic actuators and air cylinders on a coating or dosing line where the process runs at reduced regulated pressures and the low-pressure type is the better match.
Size the unit by the port and flow step: sizes 200, 300, 400 and 600 map to increasing ports, and this unit steps to 3/8 inch NPT. Choose the drain - differential-pressure (as fitted here), automatic, or manual. Filter grade is 40 um standard or 5 um with the W code, fitted here for finer protection. The embedded square gauge is standard with MPa, psi or bar scales, and an external round gauge is optional. Thread: PT is the standard, while G (BSPP) and NPT are order options - this unit carries NPT. Brackets are optional and not included with this configuration. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for this family as curves, not as a single rated figure, so we do not quote a number here. Send us your line pressure and expected air consumption and we will confirm sizing from the datasheet on request.
The W in the code selects the 5 um filter element instead of the 40 um standard, for finer protection of downstream valves and cylinders. The L selects the low-pressure regulator type for circuits running at reduced pressures; its exact adjustment range is not published, so confirm it with us before ordering.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.