The AirTAC GFR300C10MJF3TK AirTAC Filter Regulator NPT3/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR300C10MJF3TK is an AirTAC GFR filter regulator: one body removes water and particulate from compressed air and holds the downstream pressure at your set point. This size 300 unit has a 3/8 in NPT port, a metal bowl with manual drain, a 40 um filter element, an embedded square gauge scaled in bar, and a reverse (check) valve fitted; no mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi), the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi), and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 in, and options including automatic or differential-pressure drains, a 5 um filter element (code W), gauge scales in MPa, psi or bar, an external round gauge, G (BSPP) or NPT threads in place of the PT standard, and a mounting bracket. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.
| Model | GFR300C10MJF3TK AirTAC Filter Regulator NPT3/8 |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C1 (two-unit set) |
Filtered, regulated air feeding the tool-clamp and chip-extraction cylinders on a CNC machining center, with the check valve holding the set pressure if the main supply dips.
Supplying carton-sealing and case-erector cylinders on a packaging line, where the 40 um element keeps water and pipe scale out of the directional valves.
A compact filter-regulator stage in the air supply panel of a robotic welding cell, letting the integrator set pressure locally at the cell instead of at the compressor room.
Size 300 with a 3/8 in NPT port suits lines whose air demand falls in that port's flow band; step down to size 200 for smaller demand or up to 400/600 for larger, and we will confirm the flow curves against your application before you order. This configuration is fixed at: manual drain, 40 um filtration, square gauge in bar, check valve fitted, no bracket. If you would rather have automatic or differential-pressure draining, 5 um filtration (code W), a gauge in MPa or psi, or a bracket, the same series carries those options. Thread: PT is the AirTAC standard and G (BSPP) and NPT are catalogue options ordered by suffix - this unit is ordered in NPT.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Tell us your line pressure and the air your equipment needs, and we will confirm sizing against the datasheet before you order.
This unit carries drain code M: you open the drain at the bottom of the bowl by hand to release collected water. If you prefer automatic or differential-pressure draining, those options are available in the same GFR series - just ask when ordering.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.