The AirTAC GFR300C10MLC2W AirTAC Filter Regulator PT3/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR300C10MLC2W is an AirTAC GFR300 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is built on a PT3/8 port, carries the 5 um filter element (the finer of the two published grades), a metal bowl with manual drain, the low-pressure regulator type, and a round gauge scaled in psi; a mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
It is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, and options for drain type, filter grade, gauge style and scale, thread (PT standard; G and NPT to order) and bracket. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing or any datasheet figure for your application before ordering.
| Model | GFR300C10MLC2W AirTAC Filter Regulator PT3/8, 5 um |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C1 (two-unit set) |
Point-of-use air preparation for the clamping fixtures on a machining cell: the 5 um element keeps swarf-adjacent valve and cylinder air clean, while the regulator holds the set pressure the fixture was designed around.
Feeding pilot valves and small actuators on a bottling or packaging line that runs at reduced pressure: the low-pressure regulator type matches circuits set below the standard band, and the manual-drain bowl is emptied during line cleaning rounds.
A filtered, regulated supply for pressure sensors, transducers and pneumatic controls on an in-house test bench, where the round psi gauge gives a direct readout in the units the bench instrumentation uses.
The real choices on this family: step size and port (200/300/400/600, 1/8 to 1 inch) against the flow your line needs; drain type - differential-pressure (default), automatic, or manual as fitted here, which you open periodically to empty collected water from the bowl; filter grade 40 um standard or 5 um as fitted here for finer particulate; gauge style and scale (embedded square gauge standard, external round gauge optional, MPa/psi/bar); thread PT standard with G (BSPP) and NPT as order options; and bracket. Flow is published as curves, not a single rating, so send us your application and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as curves, not as a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and the full datasheet figures for this unit on request.
Manual drain means you open the drain yourself at intervals to empty water collected in the metal bowl, rather than relying on an automatic or differential-pressure drain. The W code sets the 5 um element in place of the 40 um standard, giving finer particulate capture for downstream valves and instruments.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.