The AirTAC 4V330E-10BI Solenoid Valve, 5/3-way, exhaust center, PT3/8, DC24V, grommet entry (4V330E10BI) is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with PT3/8 ports and an effective area of 21.3 mm² (Cv 1.25). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V330E-10BI is a 5/3-way double-solenoid pneumatic directional valve built on the 4V300 body, pre-wired with a DC24V grommet-style coil. In its center position both cylinder ports are exhausted to atmosphere, allowing a double-acting actuator to float freely when neither solenoid is energised—ideal for applications where the load must be moved by hand during a pause or where pressure must not be trapped.
With an effective area of 21.3 mm² (Cv 1.25, catalog figure for the 4V330C-10) and a maximum cycling rate of 3 cycles per second, this valve suits double-acting cylinders in the ~Ø50–80 mm range. The DC24V coil draws just 3.0 W, and the spool shifts in 0.05 s or less. The IP65-rated aluminium body includes a locking manual override and can be mounted on a manifold base for multi-valve groups.
| Model | AirTAC 4V330E-10BI Solenoid Valve, 5/3-way, exhaust center, PT3/8, DC24V, grommet entry (4V330E10BI) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Exhaust center |
| Port size | PT3/8 |
| Exhaust port | PT1/4 |
| Effective area (Cv) | 21.3 mm² (Cv 1.25) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 450 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 21.3 mm² |
|---|---|
| Flow coefficient | Cv 1.25 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -10 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
Operators can freely reposition a cylinder rod by hand during the exhaust-center pause, speeding up part changeover on assembly jigs without fighting trapped air pressure.
Drives a double-acting clamp that goes completely slack at center, eliminating the risk of a clamp staying partially engaged when the machine cycle is interrupted.
Controls a transfer pusher that can be manually retracted for jam clearance; the exhaust center lets the cylinder float, protecting the actuator and product from damage.
Choose the 4V330E when you need a double-acting cylinder to go limp at mid-stroke—common in manual-load stations or clamping circuits where trapped pressure would be a safety hazard. The 4V300 body sits between the smaller 4V200 (Cv 1.0) and the larger 4V400 (Cv 2.82); step down to a 4V200 for cylinders below about Ø40 mm, or up to a 4V400 for bores above Ø80 mm. This SKU is factory-configured with a DC24V coil and a grommet entry, so you get a 0.5 m flying lead instead of a terminal box—convenient for DIN-rail wiring. When replacing an existing valve, match all five points: body size (4V300), 5/3 exhaust-center function, 3/8 in PT-threaded ports, DC24V voltage, and grommet electrical connection.
AirtacDistr lists every 4V330E-10 order code with its price on one page at https://airtacdistr.com/products/airtac-4v330e-10-solenoid-valve
Quick checklist
When both solenoids are de-energised, the valve spool returns to center and connects both cylinder ports (A and B) to exhaust while blocking the inlet port. This lets a double-acting cylinder rod move freely by external force—often called a 'float' position. It is not a holding or braking function.
Yes, electrically it is the same DC24V 3.0 W coil. The difference is the wiring entry: the 'I' suffix means it comes with a 0.5 m flying lead sealed by a grommet instead of a screw-terminal box. Make sure your cable management accepts a DIN-style lead-out, and verify that your port thread is 3/8 in PT.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.