This model is discontinued
AirTAC has phased out the MAL series. The drop-in replacement is ACED50X25LB — same bore, stroke, output force, port and mounting, so it fits the same application. Simply order the ACED50X25LB in place of this model. The ACE replacement is a current-production ISO 21287 compact cylinder in the same bore, stroke and force class, with a matching short body and the same mounting-accessory family, so it fits the same envelope. Confirm mounting-interface dimensions against the ACE datasheet before ordering.

The AirTAC Airtac ACPD Double Rod Compact Cylinder ACPD50X25LB is a double acting, double rod DIN-standard tight/compact air cylinder with a Ø50mm bore and 25mm stroke, 1/8" air ports and a hard-anodized aluminium body. This model is discontinued — the current-production replacement is the ACED50X25LB (ISO 21287 ACE), in the same bore, stroke and force class.
A double acting compact cylinder with a rod leaving both covers, the ACPD50X25LB pushes and pulls with identical output: 881.2 N at 0.5 MPa and 1233.7 N at 0.7 MPa in either direction, because both strokes work on the rod-side area of the 50 mm bore. The through-rod resists rotation and side load, gives a symmetric mount, and the rear rod can carry a sensor flag. Stroke is a short 25 mm, so the body fits jigs and fixtures where a full-length cylinder cannot.
The hard-anodized aluminium body with an S45C hard-chrome rod uses a fixed TPU bumper at each end and runs at 30-500 mm/s on air filtered to 40 um, across 0.15-1.0 MPa (22-145 psi). As a rule of thumb, plan on roughly 529 N of usable work at 0.5 MPa, which lifts about 54 kg vertically with a 2:1 margin. Note this model is discontinued: the current-production drop-in is the ISO 21287 ACED50X25, so confirm mounting dimensions before swapping.
| Model | Airtac ACPD Double Rod Compact Cylinder ACPD50X25LB |
|---|---|
| Series | ACPD DIN compact cylinder (discontinued) |
| Replacement | ACED50X25LB |
| Bore size | Ø50 mm |
| Stroke | 25 mm |
| Acting type | Double acting, double rod |
| Port size | 1/8" |
| Rod thread | M10×1.5 |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Operating pressure | 0.15 – 1.0 MPa |
| Proof pressure | 1.5 MPa |
| Temperature | -20 to +70 °C |
| Speed range | 30 – 500 mm/s |
| Cushion | Fixed bumper (both ends) |
| Max standard stroke | Up to 250 mm |
Specifications follow the official AirTAC ACP datasheet (now discontinued). The ACED50X25LB (ISO 21287) carries the same bore/stroke/force class; confirm mounting-interface dimensions against the ACE datasheet before installation. Rod type: female thread (blank) or male thread (B). Thread options: PT (blank) / G.
| Pressure | Force (both ways) |
|---|---|
| 0.5 MPa | 881 N |
| 0.7 MPa | 1234 N |
| Max (@1.0 MPa) | 180 kgf |
Double-rod: a rod exits both covers, so output force is equal in both directions (rod-side area used).
| ACPD | DIN compact cylinder (double-rod, discontinued). |
|---|---|
| 50 | Bore size in mm. |
| ×25 | Stroke length in mm. |
| S | Optional built-in magnet for sensor position sensing (omit for no magnet). |
| B | Rod type: B = male thread; blank = female thread. |
Replacement mapping (swap P for E): ACP→ACE, ASP→ASE, ATP→ATE, ACPD→ACED, ACPJ→ACEJ. ACP-family: ACP (double acting), ASP / ATP (single acting push / pull), ACPD (double rod), ACPJ (adjustable stroke).
The 25 mm stroke and equal 881.2 N force in both directions let a machining fixture clamp and release with the same force, using one cylinder instead of two single-rod units.
A packaging line slide uses the rear rod to return the carrier, so the same 1233.7 N at 0.7 MPa drives the stroke out and back at 30-500 mm/s.
On a gantry positioner, the back-end rod carries a flag plate; with the optional -S magnet ordered, CMSE or DMSE switches report end positions without extra hardware.
At 881.2 N per direction, this 50 mm bore suits clamping and transfer jobs needing 60-80 kgf of balanced force. Step down to the 40 mm bore (571.8 N at 0.5 MPa) for lighter loads, or up to 63 mm (1458.1 N) when more thrust is needed. The through-rod keeps the fixture symmetric, and the LB foot brackets bolt to standard ISO 21287 faces. This cylinder drifts when air is lost, so add a rod lock or pilot check for held loads. No magnet is fitted here; order the -S code if you later need CMSE or DMSE switches. Replacement: ACED50X25.
Replacement checklist
Because a rod exits both covers, force is equal in both directions: 881.2 N at 0.5 MPa and 1233.7 N at 0.7 MPa on the rod-side area, with a maximum of 179.7 kgf at 1.0 MPa. Operating range is 0.15-1.0 MPa (22-145 psi), proof pressure 1.5 MPa (215 psi), speed 30-500 mm/s, temperature -20 to +70 C, on air filtered to 40 um.
The short ISO 21287-class body saves about 50% of the mounting length of an ISO 15552 profile cylinder, with a fixed TPU bumper at each end and LB foot mounting on a standard face. The ACPD family is discontinued; the current drop-in is the ACED50X25 (swap the P for an E), same bore, stroke and force class - confirm the ISO 21287 mounting dimensions before swapping.
Send us the quantity and destination. We confirm price, stock and lead time on the ACED50X25LB replacement — usually within 7-8 hours.