AirTAC GL300 · Air Lubricator (oil-mist lubrication)

Airtac B52-GL Copper-Free Air Treatment Unit B52-GL300C10J

The AirTAC Airtac B52-GL Copper-Free Air Treatment Unit B52-GL300C10J is a genuine G-series air lubricator. It meters an oil mist into the compressed-air line so cylinders, valves and air tools downstream stay lubricated, with See datasheet ports and a pc oil bowl. A lubricator does not filter or regulate — it goes last in the line, after the filter and the regulator.

  • TypeAir lubricator
  • Port sizeSee datasheet
  • Inlet pressure0.05 - 1.0 MPa
  • Oil bowlPC
  • ThreadPT
  • BracketMounting bracket included
$33.19 $37.70Save 11% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GL Copper-Free Air Treatment Unit B52-GL300C10J

The AirTAC GL series is a dedicated air lubricator: it adds a fine oil mist to a compressed-air line and nothing else - there is no filtration and no pressure regulation in this unit. GL300C10J is the size 300 body with a PT3/8 port (PT is the standard thread; G and NPT are catalogue thread options). The PC (polycarbonate) bowl holds the oil, the maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C, non-freezing. The J suffix means no mounting bracket is fitted.

This is a genuine AirTAC part distributed for the US market. The GL series is available in sizes 200, 300, 400 and 600, each in a range of port sizes, with or without the mounting bracket, and in PT, G (BSPP) or NPT thread. Lubricator flow is published as curves rather than a single rated number, so ask us to confirm the datasheet and sizing for your application.

Airtac B52-GL Copper-Free Air Treatment Unit B52-GL300C10J Technical Specifications

ModelAirtac B52-GL Copper-Free Air Treatment Unit B52-GL300C10J
SeriesGL300 air lubricator
Port sizeSee datasheet (PT thread)
Oil bowl materialPC
BracketMounting bracket included
FluidCompressed air
Inlet pressure0.05 - 1.0 MPa (7 - 145 psi)
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
FunctionOil-mist lubrication only

Specifications follow the official AirTAC G-series air-preparation data. A lubricator has no drain, no regulating mechanism, no gauge and no filter element, so none of those figures apply. Oil grade, bowl capacity, flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GL Copper-Free Air Treatment Unit B52-GL300C10J

GL300G-series air lubricator, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Mounting bracket included. A bracket ships by default; J orders it without.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.

The lubricator has the shortest code of the six G-series subfamilies — size, port, bracket, thread. There is no drain, pressure-type, gauge or filtering-grade position. Example: GL300-10JG is a 300 body, PT3/8", no bracket, G (BSPP) thread.

Size Class

  • GL200PT1/8" - PT1/4"
  • GL300PT1/4" - PT1/2"
  • GL400PT3/8" - PT1/2"
  • GL600PT3/4" - PT1"

A larger body carries a larger port and passes more air. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GL600 uses an aluminium-alloy oil bowl; the 200, 300 and 400 bodies use PC.

This modelGL300 · See datasheet
One size downGL200
One size upGL400
Line orderFilter first, then regulator, lubricator last

Where the Airtac B52-GL Copper-Free Air Treatment Unit B52-GL300C10J Is Used

handyman

Workshop air tool drop lubrication

Installed in the drop from an overhead air line to a workbench, oiling grinders, drills and screwdrivers used across a shift.

view_module

Injection moulding machine actuator feed

Feeding oil mist to the pneumatic actuators that operate slides and ejectors on an injection moulding machine, mounted directly in the machine air circuit.

local_shipping

Trailer brake and door actuator supply

Lubricating the air cylinders that open and close curtains and tail lifts on commercial vehicle assembly and service lines.

Is the Airtac B52-GL Copper-Free Air Treatment Unit B52-GL300C10J the Right Lubricator?

Step up or down through the 200/300/400/600 sizes to match the port and flow path you need; size 300 here carries a 3/8 inch port. Thread: PT is the standard for this code - order the G (BSPP) or NPT variant if your pipework requires it. The J suffix deletes the mounting bracket, so plan for direct line mounting or your own fixing method; the non-J version includes the bracket. Because lubricator flow is published as curves and not as a single rating, ask us to confirm sizing against your air consumption before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Downstream equipment actually needs oil
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Bracket needed, or order with J
  • ✓ Bowl material: PC, or aluminium on GL600
  • ✓ Fit after the filter and regulator
Ask an Engineer

Installation & Maintenance Notes

  • check Fit last in the line: filter, then regulator, then lubricator.
  • check Mount vertically, bowl down, following the airflow arrow.
  • check Keep inlet pressure within 0.05 - 1.0 MPa.
  • check Use only oil approved for pneumatic lubricators.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Check the oil level regularly; top up before it runs dry.

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The oil mist travels downstream, so if any branch of the line must stay oil-free, take that branch off before the lubricator. We will confirm the recommended oil grade from the factory datasheet on request.

Airtac B52-GL Copper-Free Air Treatment Unit B52-GL300C10J FAQ

AirTAC publishes lubricator flow as curves, not as a single rated figure, so there is no one number to quote here. Send us your line pressure and air consumption and we will confirm the sizing and provide the datasheet on request.

It means the unit comes without the mounting bracket. Function, size 300 body, PT3/8 port, PC bowl and the -5 to 70 C working range are the same as the bracketed GL300C10; only the fixing hardware differs.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GL Copper-Free Air Treatment Unit B52-GL300C10J

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GL300C10J and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.