The AirTAC Airtac GAC F.R.L. Unit GAC20006LK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for single actuators, this AirTAC GAC20006LK combines a filter, regulator and lubricator on one L-shape bracket. The 1/8in port feeds a lower-pressure circuit operating between 0.15-0.4 MPa (20-58 psi), trapping 40 um particles before the oil mist is added downstream of the regulator seat. A circular gauge reading MPa/psi is fitted for the default PT thread.
Weighing 750 g, the assembly carries a 25 cc condensate bowl and a 36 cc oil reservoir. This model includes a reverse-flow (reflux) valve, which the catalogue shows as a separate pneumatic symbol with details on its own page. The semi-auto and manual drain pair is fitted, and the unit is rated for -5 to 70 C using ISO VG 32 lubricant.
| Model | Airtac GAC F.R.L. Unit GAC20006LK |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF200-06 filter, GAR200-06 regulator, GAL200-06 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/8" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds individual actuators on benchtop assembly jigs where a 1/8in port and a 36 cc oil bowl provide sufficient capacity for light, intermittent duty.
Conditions supply air for laboratory test fixtures requiring stable low-pressure outputs between 0.15 and 0.4 MPa without over-pressurizing delicate instruments.
Prepares air for small handheld pneumatic tools by adding a controlled oil mist downstream of the regulator to keep internal moving parts lubricated.
Choose this 1/8in body for small jigs where space is tight, stepping up to the GAC300 if you need a larger 60 cc drain bowl or a flow envelope plotted to 3000 L/min at 0.7 MPa inlet. The PC bowl suits general machinery at the standard 1.0 MPa maximum, while the lower-pressure type caps the outlet at 0.4 MPa. If the downstream line must stay oil-free, choose a filter-regulator instead of this lubricated assembly. Replacement spares share the 200-06 suffix: GAF200-06, GAR200-06 and GAL200-06. The 0.4 MPa upper limit is 44% of the standard 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 750 g, has a 25 cc drain bowl and a 36 cc oil bowl, and uses ISO VG 32 lubricant.
The K indicates a reverse-flow (reflux) valve is fitted. The AirTAC catalogue draws this as a separate pneumatic symbol on its own page, and no functional details are provided in our source data.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.