verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAC200 · F.R.L. Combination (Filter + Regulator + Lubricator)

Airtac GAC F.R.L. Unit GAC20006LNK

The AirTAC Airtac GAC F.R.L. Unit GAC20006LNK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/8"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialPC
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight750 g
$73.27 $81.91Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAC F.R.L. Unit GAC20006LNK

Delivering cleaned, regulated and lubricated air for light-duty pneumatics, this GAC20006LNK combination integrates a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 1/8in port serves small actuators, while the lower-pressure type restricts the operating band to 0.15-0.4 MPa (20-58 psi). A 40 um element captures particulates before the regulator, ensuring the internal seat stays clean.

Because the letter N follows the port code, no pressure gauge is supplied from the factory; operators can add one via the 1/8in gauge connection. This specific assembly carries the reverse-flow (reflux) valve, which the catalogue depicts as a separate pneumatic symbol with details on its own page. Condensate empties through a paired semi-auto and manual drain into a 25 cc bowl, and the unit weighs 750 g.

Airtac GAC F.R.L. Unit GAC20006LNK Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC20006LNK
SeriesGAC200 F.R.L. combination
Port size1/8" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialPC
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl25 cc
Capacity of oil bowl36 cc
Recommended lubricantISO VG 32 or equivalent
Weight750 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.

Model Code: Airtac GAC F.R.L. Unit GAC20006LNK

GAC200GA200 series F.R.L. unit — sets ports, bowl capacity and weight.
(blank)Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N).
06Port size 1/8". This body offers 06 = 1/8", 08 = 1/4".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/8" gauge connection.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAF200-06 filter, GAR200-06 regulator, GAL200-06 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC200 · 1/8" · curve to 1750 L/min
One size upGAC300 (curve to 3000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC20006LNK Is Used

precision_manufacturing

Micro-Assembly Jigs

Feeds low-force grippers handling delicate electronics where a maximum 0.4 MPa output prevents crushing components.

science

Laboratory Air Tools

Conditions supply for benchtop test fixtures requiring a steady, lower-pressure air source with added lubrication.

straighten

Small Instrumentation

Prepares air for sensitive pneumatic gauges and low-pressure cylinders that cannot tolerate standard 0.9 MPa outputs.

Is the Airtac GAC F.R.L. Unit GAC20006LNK the Right Air-Prep Unit?

Choose this 750 g assembly for single actuators where space is tight, stepping up to the GAC300 if you need a larger 60 cc condensate bowl. The PC bowl is standard for general environments, while the semi-auto and manual drain pair dumps water on every pressure drop or on demand. Since this is the lower-pressure type, the regulator tops out at 0.4 MPa, making it the wrong part if the machine might ever need higher force. Remember that oil mist is added downstream of the regulator, so choose a filter-regulator instead if the line must stay oil-free. Replacement spares share the exact same body and port suffix: GAF200-06, GAR200-06 and GAL200-06. Note that 0.4 MPa is about 44% of the Standard type's 0.9 MPa ceiling, quantifying exactly what the buyer gives up when choosing this lower-pressure variant.

Quick checklist

  • ✓ Body size for your peak flow (1/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 25 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 750 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC20006LNK FAQ

This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 750 g, features a 25 cc drain bowl and a 36 cc oil bowl, and uses ISO VG 32 lubricant.

The N after the port means no gauge is supplied, though a 1/8in connection exists to fit one later. The K indicates a reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue, with details on its own page.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC20006LNK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAC20006LNK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.