The AirTAC Airtac GAC F.R.L. Unit GAC200C06ASNWK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for small pneumatic jigs, this AirTAC combination mounts a filter, regulator and lubricator on a single L-shape bracket with quick clamps. The 1/8in port pairs with a 5 um element to trap fine particles before they reach precision valves. Air passes through the filter first, then the regulator sets the 0.15-0.9 MPa (20-130 psi) working pressure, and oil mist is added last so it never fouls the regulator seat.
Because no gauge is supplied, the set pressure cannot be read without adding one to the 1/8in gauge connection. The metal bowl equips this unit for rugged environments, while the automatic drain clears condensate without an operator. A reverse-flow (reflux) valve is fitted, which the catalogue shows as a separate pneumatic symbol with details on its own page. If the downstream line must stay oil-free, choose a filter-regulator instead and omit the lubricator.
| Model | Airtac GAC F.R.L. Unit GAC200C06ASNWK |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF200-06 filter, GAR200-06 regulator, GAL200-06 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/8" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds single small-bore cylinders on testing fixtures where a 5 um element protects delicate seals from fine particulate ingress.
Conditions supply for benchtop pneumatic pick-and-place arms, relying on the automatic drain to keep the 25 cc bowl empty during unattended overnight runs.
Prepares air for miniature screwdrivers and clamps, adding a controlled oil mist downstream of the regulator to prolong tool life.
This 750 g assembly is the smallest size class, needing a proper panel or frame mount rather than support from the tubing. The 25 cc condensate bowl and 36 cc oil bowl drive the service interval, requiring more frequent attention than larger bodies. The automatic drain suits unattended or wet lines, and the 5 um element protects instrument air at the cost of more frequent element service. The three units are separately orderable as GAF200-06, GAR200-06 and GAL200-06, so a clogged element does not mean replacing the whole assembly. Stepping up to the GAC300 body shifts the plotted flow envelope from 1750 to 3000 L/min at 0.7 MPa inlet, an increase of about 1.7x for higher demand.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, uses a 5 um element, weighs 750 g, holds 25 cc of condensate and 36 cc of oil, and recommends ISO VG 32 lubricant.
The N in the ordering code means no gauge is supplied. The body features a 1/8in gauge connection, so you must add your own gauge to read the set pressure. The default PT thread sets the gauge scale to MPa/psi if one is installed later.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.