
The AirTAC Airtac GAC F.R.L. Unit GAC200C06S is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Supplying clean, regulated and lubricated air to a single actuator, this GAC200C06S combination pre-assembles a filter, regulator and lubricator on one L-shape bracket with quick mounting clamps. The 1/8in port feeds the standard 0.15-0.9 MPa (20-130 psi) range, and the 40 um element captures solid grain before it reaches downstream valves. A circular gauge is fitted, reading MPa/psi for the default PT thread.
The metal bowl equips this unit for rugged environments where a standard PC bowl might risk impact, while the integrated semi-auto and manual drain pair handles condensate removal. Weighing 750 g, the assembly needs a proper panel or frame mount rather than tubing support. Air passes filter, then regulator, then lubricator, ensuring oil mist is added downstream so the regulator seat never fouls.
| Model | Airtac GAC F.R.L. Unit GAC200C06S |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF200-06 filter, GAR200-06 regulator, GAL200-06 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/8" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds precisely regulated and lubricated air to small robotic grippers handling delicate electronics assembly.
Conditions supply for light-duty benchtop grinders or drills in a single workshop station.
Prepares driving air for sensitive lab automation cylinders requiring stable low-flow pressure.
This 1/8in unit suits light-duty jigs, with a 25 cc condensate bowl and a 36 cc oil reservoir dictating frequent maintenance checks. If your machine requires finer protection, the 5 um element (W code) traps smaller particles for precision instrumentation. Because the lubricator introduces oil mist downstream, select a separate filter-regulator if the line must remain oil-free. The three units are separately orderable as GAF200-06, GAR200-06 and GAL200-06, so a damaged component does not require replacing the whole assembly. Stepping up to the GAC300 body shifts the plotted flow curve from 1750 L/min to 3000 L/min at 0.7 MPa inlet, an envelope increase of roughly 1.7x.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
It operates at 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It features a 25 cc drain bowl, a 36 cc oil bowl, a 40 um element, and uses ISO VG 32 lubricant. The unit weighs 750 g.
The C in the code denotes a metal bowl, chosen for environments requiring higher impact resistance than standard PC. Because there is no A in the code, it ships with both a semi-auto drain (which dumps on pressure drop) and a manual drain for on-demand emptying.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.