verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GAC200 · F.R.L. Combination (Filter + Regulator + Lubricator)

Airtac GAC F.R.L. Unit GAC200N08ALNTK

The AirTAC GAC F.R.L. Unit GAC200N08ALNTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/4"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialNylon
  • Drainautomatic
  • Pressure gaugeNot fitted
  • Weight750 g
$88.53 $96.03Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GAC200-08 bowl, type and element option on one page All GAC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the Airtac GAC F.R.L. Unit GAC200N08ALNTK

Delivering cleaned, regulated and lubricated air for light-duty pneumatics, this GAC200 unit combines a filter, regulator and lubricator on a single L-shape bracket. It features a 1/4in port, a 40 um element and a lower pressure operating range of 0.15-0.4 MPa (20-58 psi). The automatic drain clears condensate from the 25 cc bowl without an operator, while the nylon bowl keeps the assembly weight to 750 g.

Because no gauge is supplied, the set pressure cannot be read without adding one to the 1/8in gauge connection. The reverse-flow (reflux) valve is fitted, which the catalogue shows as a separate pneumatic symbol with details on its own page. Air passes through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. Order code GAC200N08ALNTK has NPT ports (the T in the code) for North American pipe fittings.

Airtac GAC F.R.L. Unit GAC200N08ALNTK Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC200N08ALNTK
SeriesGAC200 F.R.L. combination
Port size1/4" (NPT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialNylon
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl25 cc
Capacity of oil bowl36 cc
Recommended lubricantISO VG 32 or equivalent
Weight750 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.

Model Code: Airtac GAC F.R.L. Unit GAC200N08ALNTK

GAC200GA200 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
08Port size 1/4". This body offers 06 = 1/8", 08 = 1/4".
ADrain: Automatic drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/8" gauge connection.
(blank)Filtering grade 40 µm.
TNPT thread; gauge scale psi / bar.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAF200-08 filter, GAR200-08 regulator, GAL200-08 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC200 · 1/4" · curve to 1750 L/min
One size upGAC300 (curve to 3000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC200N08ALNTK Is Used

precision_manufacturing

Small Pneumatic Jigs

Feeds single-actuator jigs and low-force clamping fixtures requiring stable, low-pressure air below 0.4 MPa.

handyman

Benchtop Assembly Tools

Conditions air for light handheld drivers and benchtop assembly stations where a 1/4in port is standard.

science

Lab Testing Equipment

Regulates sensitive laboratory pneumatic setups, adding controlled oil mist for moving parts while using the auto drain for unattended operation.

Is the Airtac GAC F.R.L. Unit GAC200N08ALNTK the Right Air-Prep Unit?

Choose this lower-pressure type if your machine operates strictly within 0.15-0.4 MPa (20-58 psi); if the application may ever need more, the L type is the wrong part. The 40 um element suits general plant air, whereas the 5 um option (W) traps finer particles for precision valves at the cost of more frequent service. If the downstream line must stay oil-free, omit the lubricator and choose a filter-regulator instead. For maintenance, the three units are separately orderable as GAF200-08, GAR200-08 and GAL200-08, so a clogged element does not require replacing the whole assembly. Stepping up to the GAC300 roughly doubles the flow envelope from 1750 to 3000 L/min at 0.7 MPa inlet, but the 0.4 MPa ceiling is 44% of the standard 0.9 MPa maximum.

Quick checklist

  • ✓ Body size for your peak flow (1/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 25 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 750 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC200N08ALNTK FAQ

This lower-pressure unit operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It has a 1/4in port, a 25 cc drain bowl, a 36 cc oil bowl, and weighs 750 g. The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32.

No, the N in the code means no gauge is supplied. To read the outlet pressure, you must add a gauge to the 1/8in connection. The default NPT thread sets the gauge scale to MPa/psi if one is installed later.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC200N08ALNTK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GAC200N08ALNTK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.