The AirTAC GAC F.R.L. Unit GAC200N08ASNWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, the GAC200N08ASNWT is a three-unit F.R.L. combination pre-plumbed on a single L-shape bracket. This 1/4in port model uses a nylon bowl and a 5 um element to trap fine particles, operating across a 0.15-0.9 MPa (20-130 psi) standard pressure range.
Because no gauge is supplied, the set pressure cannot be read without adding one to the 1/8in gauge connection. The automatic drain clears condensate without an operator, and the 25 cc drain bowl paired with a 36 cc oil reservoir dictates the maintenance frequency for this 750 g assembly. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC200N08ASNWT |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF200-08 filter, GAR200-08 regulator, GAL200-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds clean, lubricated air to sensitive directional valves in small pneumatic logic circuits where the 5 um element prevents sticking.
Conditions air for single-actuator bench grinders or light assembly jigs, with the automatic drain handling condensate during intermittent use.
Supplies stable pressure to compact lab pick-and-place units, relying on the nylon bowl for a lightweight, non-corrosive installation.
Choose this compact body for single actuators or small jigs where space is tight. The 5 um element traps far finer particles than the standard 40 um grade, making it ideal for precision valves, though it requires more frequent element service. If the downstream line must stay oil-free, omit the lubricator and choose a filter-regulator instead. For maintenance, the three units are separately orderable as GAF200-08, GAR200-08 and GAL200-08. Stepping up to the GAC300 body shifts the plotted flow envelope from 1750 L/min to 3000 L/min at 0.7 MPa inlet, an increase of roughly 1.7x.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type operates at 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, the drain bowl holds 25 cc, the oil bowl holds 36 cc, the unit weighs 750 g, and the recommended lubricant is ISO VG 32.
The N after the port code indicates no gauge is supplied. To read the set pressure, a circular gauge must be added to the 1/8in gauge connection, which will read in MPa/psi for the default NPT thread.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.