The AirTAC GAC F.R.L. Unit GAC200N08SNT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination
  • Port size1/4"
  • Pressure range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • Bowl materialNylon
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight750 g
$68.92 $76.42Save 9% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GAC200-08 bowl, type and element option on one page All GAC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the Airtac GAC F.R.L. Unit GAC200N08SNT

Delivering cleaned, regulated and lubricated air for downstream pneumatics, this AirTAC F.R.L. combination pre-assembles a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 1/4in port pairs with a 40 um element and a standard pressure range of 0.15-0.9 MPa (20-130 psi). Air passes through the filter first, then the regulator, before oil mist is introduced last by the lubricator, ensuring the regulator seat never gets fouled by oil.

This variant uses a nylon bowl and ships without a pressure gauge, though a 1/8in gauge connection is provided if you need to add one later. Weighing 750 g, the assembly carries a 25 cc condensate bowl and a 36 cc oil reservoir. The unit operates between -5 to 70 C, and because no gauge is supplied, the set pressure cannot be read without adding a separate instrument. Order code GAC200N08SNT has NPT ports (the T in the code) for North American pipe fittings.

Airtac GAC F.R.L. Unit GAC200N08SNT Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC200N08SNT
SeriesGAC200 F.R.L. combination
Port size1/4" (NPT thread)
Filtering grade40 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
TypeStandard
Bowl materialNylon
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl25 cc
Capacity of oil bowl36 cc
Recommended lubricantISO VG 32 or equivalent
Weight750 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.

Model Code: Airtac GAC F.R.L. Unit GAC200N08SNT

GAC200GA200 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
08Port size 1/4". This body offers 06 = 1/8", 08 = 1/4".
(blank)Drain: Semi-auto drain + manual drain.
SStandard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/8" gauge connection.
(blank)Filtering grade 40 µm.
TNPT thread; gauge scale psi / bar.
(blank)No reverse-flow valve.

Constituent units, orderable separately as spares: GAF200-08 filter, GAR200-08 regulator, GAL200-08 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC200 · 1/4" · curve to 1750 L/min
One size upGAC300 (curve to 3000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC200N08SNT Is Used

handyman

Benchtop Tooling

Feeds a single pneumatic pick-and-place head or small desktop jig requiring a steady 1/4in air supply with added oil mist.

straighten

Small Actuator Lines

Conditions air for compact clamping cylinders on a secondary assembly station where floor space is limited.

science

Lab Automation

Prepares supply air for low-flow analytical or testing fixtures that rely on a 40 um element to protect internal valves.

Is the Airtac GAC F.R.L. Unit GAC200N08SNT the Right Air-Prep Unit?

Choose this GAC200 body for single actuators or small jigs, stepping up to the GAC300 if you need a larger 60 cc drain bowl or a higher flow envelope plotted to 3000 L/min at 0.7 MPa inlet. This model carries a semi-auto and manual drain pair, meaning the semi-auto dumps condensate on every pressure drop while the manual option allows on-demand emptying. The nylon bowl suits standard plant environments, and if the downstream line must stay completely oil-free, you should omit the lubricator entirely and choose a separate filter-regulator instead. Replacement spares follow the body and port directly: GAF200-08, GAR200-08 and GAL200-08. Keep in mind the 1.5 MPa (215 psi) proof pressure provides a 1.5x burst-test margin over the 1.0 MPa maximum, which is not permission to run above the limit.

Quick checklist

  • ✓ Body size for your peak flow (1/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 25 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 750 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC200N08SNT FAQ

This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates in temperatures from -5 to 70 C, weighs 750 g, and features a 25 cc drain bowl alongside a 36 cc oil bowl. The recommended lubricant is ISO VG 32.

The N in the ordering code indicates no gauge is supplied. The body has a 1/8in gauge connection machined in, so you can install your own pressure indicator to read the setpoint, but you cannot verify the downstream pressure without adding that component.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC200N08SNT

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GAC200N08SNT and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.