The AirTAC GAC F.R.L. Unit GAC30008ALNWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air, this AirTAC assembly integrates a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. It features a 1/4in port, a 5 um element for fine particle retention, and operates at 0.15-0.4 MPa (20-58 psi) for lower-pressure pneumatics.
The automatic drain clears condensate from the 60 cc bowl without an operator, making it suitable for unattended wet lines. Because no gauge is supplied, the set pressure cannot be read without adding one to the 1/8in gauge connection. Oil mist is added downstream of the regulator, keeping the internal seat clean. Order code GAC30008ALNWT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC30008ALNWT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-08 filter, GAR300-08 regulator, GAL300-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/4" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure instrument air to sensitive solenoid valves, relying on the 5 um element to prevent particulate fouling in fine internal clearances.
Conditions air for delicate pneumatic grippers on packaging machines where a 0.4 MPa ceiling prevents crushing fragile cartons or product.
Prepares clean, lubricated air at stable low pressures for laboratory automation and small actuator setups requiring consistent gentle motion.
Choose this lower-pressure type for machines requiring up to 0.4 MPa; if the application may ever need more, select the standard type instead. The 5 um element suits precision valves but needs more frequent service than the 40 um option. If the downstream line must stay oil-free, omit the lubricator and choose a filter-regulator. Spares share the same body-port: GAF300-08, GAR300-08, GAL300-08. The GAC300 flow envelope is plotted to 3000 L/min at 0.7 MPa inlet, which is 50% of the GAC400's 6000 L/min curve. Finally, the 0.4 MPa ceiling is 44% of the standard 0.9 MPa maximum.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It weighs 1300 g, has a 60 cc drain bowl and a 98 cc oil bowl, uses a 5 um element, and runs from -5 to 70 C using ISO VG 32 lubricant.
The N in the code means no gauge is supplied. To read the downstream pressure, a circular gauge must be added to the 1/8in gauge connection on the body, matching the NPT thread scale of MPa/psi.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.