The AirTAC GAC F.R.L. Unit GAC30008ALT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this assembly pairs a filter, regulator and lubricator on a single L-shape bracket. The 1/4in ported body operates within a lower pressure range of 0.15-0.4 MPa (20-58 psi) and uses a 40 um element to trap solid particulates before they reach downstream valves.
Air passes through the filter first, then the regulator, and finally the lubricator, ensuring oil mist is added downstream of the regulator seat to prevent fouling. Fitted with an automatic drain that clears condensate without an operator, the 60 cc drain bowl and 98 cc oil bowl dictate the service interval for this 1300 g unit. Order code GAC30008ALT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC30008ALT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-08 filter, GAR300-08 regulator, GAL300-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/4" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure air to sensitive lab dosing pumps and glass-actuating clamps without risking high-pressure damage.
Supplies oil-misted air to delicate film-sealing cylinders operating well below standard industrial pressures.
Conditions air for low-tension fabric guiding actuators where precise 0.15-0.4 MPa control prevents material tearing.
Choose this configuration for machines requiring a maximum 0.4 MPa outlet, as the lower pressure type prevents accidental over-pressurization of sensitive actuators. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. If the line must stay completely oil-free, omit the lubricator and choose a separate filter-regulator instead. The three units are separately orderable as GAF300-08, GAR300-08 and GAL300-08, so a clogged element does not require replacing the whole assembly. Stepping up to the GAC400 body increases the plotted flow envelope from 3000 L/min to 6000 L/min at 0.7 MPa inlet, doubling the capacity. Note that the 0.4 MPa ceiling is 44% of the standard type's 0.9 MPa maximum.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 1300 g, and features a 60 cc drain bowl with a 98 cc oil bowl. The recommended lubricant is ISO VG 32.
The A in the ordering code signifies an automatic drain is fitted. It expels accumulated condensate from the 60 cc bowl automatically upon pressure drop, making the unit suitable for unattended installations or wet air lines where manual draining is impractical.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.