The AirTAC GAC F.R.L. Unit GAC30008ASNT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this GAC30008ASNT assembly integrates a filter, regulator and lubricator on a single L-shape bracket. It features a 1/4in port and operates within the 0.15-0.9 MPa (20-130 psi) standard pressure range. The 40 um element captures solid particulates, while the automatic drain clears condensate without operator intervention.
Because no gauge is supplied, the set pressure cannot be read directly without adding one to the 1/8in gauge connection. Weighing 1300 g, the unit carries a 60 cc condensate bowl and a 98 cc oil reservoir. Air passes through the filter first, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC30008ASNT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-08 filter, GAR300-08 regulator, GAL300-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/4" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds cleaned and lubricated air to tool changer cylinders on machining centers, ensuring smooth actuation during rapid spindle swaps.
Conditions air for the pneumatic sealing jaws on automated flow wrapping lines, maintaining steady pressure for consistent bag seals.
Supplies oil-mist lubrication to the pop-up sorting cylinders on package conveyor systems, extending actuator seal life in high-cycle duties.
Choose this 1/4in port body for mid-size duties; stepping down to the GAC200 drops the plotted flow envelope to 1750 L/min at 0.7 MPa inlet, while stepping up to the GAC400 extends it to 6000 L/min. This PC bowl model uses an automatic drain suited to unattended lines, and omits the gauge for compact installations. If the downstream line must remain oil-free, omit the lubricator and choose a filter-regulator instead. Replacement spares follow the body-port suffix exactly: GAF300-08, GAR300-08 and GAL300-08. The 1.5 MPa proof pressure provides a 1.5x burst-test margin above the 1.0 MPa maximum, which is a safety rating rather than permission to operate above the limit.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This model operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It functions in temperatures from -5 to 70 C, uses a 40 um element, and weighs 1300 g. The drain bowl holds 60 cc and the oil bowl holds 98 cc, requiring ISO VG 32 or equivalent lubricant.
The N after the port code indicates no gauge is supplied. You can install your own gauge using the 1/8in connection on the body, which allows you to select a specific dial size or scale for your application.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.