The AirTAC GAC F.R.L. Unit GAC30008ASNWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this AirTAC GAC30008ASNWTK combines a filter, regulator and lubricator on a single L-shape bracket. The 1/4in ported unit operates within a 0.15-0.9 MPa (20-130 psi) range and uses a 5 um element to capture fine particles before they reach downstream valves. An automatic drain empties the 60 cc condensate bowl without operator intervention, making it well suited for unattended or wet air lines.
Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling of internal components. This specific configuration ships without a gauge, though a 1/8in connection is provided should you need to add instrumentation later. The reverse-flow (reflux) valve is fitted, which the catalogue shows as a separate pneumatic symbol with details on its own page. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC30008ASNWTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-08 filter, GAR300-08 regulator, GAL300-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/4" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds clean, oil-misted air to sensitive pneumatic tool-changing cylinders on machining centres where fine 5 um filtration protects tight tolerances.
Conditions air for high-speed packaging actuators, with the automatic drain handling condensate buildup during long, unattended production runs.
Supplies stable, finely filtered air to laboratory pneumatic slides and grippers, ensuring instrument accuracy without manual bowl draining.
Choose this 1300 g assembly when your setup requires precision filtration and hands-free condensate management. The 5 um element traps far finer particulates than the standard 40 um mesh, making it ideal for sensitive instrument air or precision valves, though it will require more frequent element service. The PC bowl is standard, while the automatic drain clears liquid continuously, a step up from the semi-auto and manual pair found on blank-drain codes. If your downstream process must remain strictly oil-free, omit the lubricator and select a filter-regulator instead. For maintenance, the three units are separately orderable as GAF300-08, GAR300-08 and GAL300-08, so a clogged screen or damaged bowl does not mean replacing the whole assembly.
When sizing, note that the catalogue flow curve for the GAC300 is plotted to 3000 L/min at 0.7 MPa inlet, which is roughly 1.7 times the 1750 L/min envelope of the smaller GAC200. Also consider that the 1.0 MPa maximum supply leaves only about 0.1 MPa of headroom above the 0.9 MPa standard setting, so plan a supply near 1.0 MPa if you truly need 0.9 MPa out.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 1300 g, and features a 60 cc drain bowl alongside a 98 cc oil bowl. The recommended lubricant is ISO VG 32 or equivalent.
The N in the ordering code indicates no gauge is supplied. The body features a 1/8in gauge connection, allowing you to install a compatible pressure indicator separately if you need to visually monitor the 0.15-0.9 MPa operating range.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.