The AirTAC GAC F.R.L. Unit GAC30008ASTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this GAC30008ASTK assembly integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/4in port pairs with a standard pressure range of 0.15-0.9 MPa (20-130 psi) and a 40 um element. Pre-plumbed with quick mounting clamps, the design eliminates inter-unit tubing, ensuring a leak-free installation in minutes.
Air passes through the filter first, then the regulator, before oil mist is introduced downstream by the lubricator, keeping the regulator seat free of oil. Fitted with an automatic drain, the 60 cc condensate bowl empties without operator intervention. This specific configuration includes a reverse-flow (reflux) valve, which the catalogue illustrates as a separate pneumatic symbol. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC30008ASTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-08 filter, GAR300-08 regulator, GAL300-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/4" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds clean, lubricated air at a stable pressure to pneumatic grippers and cylinders on automated assembly stations.
Conditions air for valves and moving parts in flow-wrapping equipment, where the automatic drain handles wet supply lines.
Supplies oil-misted air to pop-up sorter cylinders, ensuring consistent actuation speed and reducing seal wear.
This unit uses a PC bowl and a 40 um element, suitable for general factory air where a standard 0.15-0.9 MPa (20-130 psi) operating range is required. The circular gauge is fitted and reads in MPa/psi for the default NPT thread. If your downstream line must remain completely oil-free, omit the lubricator and choose a filter-regulator instead. For maintenance, the three units are separately orderable using the GAF300-08, GAR300-08 and GAL300-08 part numbers.
The catalogue flow curve for the GAC300 is plotted to 3000 L/min at 0.7 MPa inlet, offering 71% more flow envelope capacity than the smaller GAC200. Keep in mind the regulation headroom: since the maximum supply is 1.0 MPa and the standard type regulates to 0.9 MPa, there is only about 0.1 MPa of headroom above the top setting.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This model operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It features a 60 cc drain bowl, a 98 cc oil bowl, a 40 um element, and weighs 1300 g. The recommended lubricant is ISO VG 32.
The K indicates that a reverse-flow (reflux) valve is attached to the unit. The catalogue shows this as a separate pneumatic symbol with details on its own page. This model also features an automatic drain and a fitted circular gauge reading in MPa/psi.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.