The AirTAC GAC F.R.L. Unit GAC30008ST is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, the AirTAC GAC30008ST is a complete F.R.L. combination built on a single L-shape bracket. This 1/4in ported unit pairs a 40 um filter, a regulator and a lubricator in strict sequence, ensuring oil mist is introduced downstream of the regulator seat to prevent fouling. A circular gauge reading MPa/psi is fitted for the default NPT thread, letting operators verify the 0.15-0.9 MPa (20-130 psi) setpoint directly.
Weighing 1300 g, this body size occupies a solid mid-range class that requires a firm panel or frame mount rather than tubing support. The assembly carries a 60 cc condensate bowl and a 98 cc oil reservoir, establishing a practical service interval for routine maintenance. Condensate is managed by a paired semi-auto and manual drain, dumping liquid on pressure drops or on demand, while the unit operates reliably from -5 to 70 C using ISO VG 32 lubricant.
| Model | Airtac GAC F.R.L. Unit GAC30008ST |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-08 filter, GAR300-08 regulator, GAL300-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/4" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Prepares air for tool changer cylinders on machining centers, ensuring consistent actuation force and protecting seals from dry running.
Conditions air for pneumatic diverters and pushers in packaging lines, where steady pressure is needed to prevent jamming at high speeds.
Supplies clean, lubricated air to high-cycle label applicator cylinders, extending mechanism life and maintaining print accuracy.
This model uses a PC bowl and a 40 um element, suited to general plant air where standard particulate removal is sufficient; for precision valves, stepping up to the 5 um element variant is advised. If your machine requires absolutely oil-free downstream air, you must omit the lubricator entirely and choose a dedicated filter-regulator instead. The three constituent modules are separately orderable as GAF300-08, GAR300-08 and GAL300-08, meaning a damaged bowl or clogged filter does not require replacing the whole assembly. When sizing, note the catalogue flow curve for the GAC300 is plotted to 3000 L/min at 0.7 MPa inlet, exactly double the 1750 L/min envelope of the smaller GAC200. Finally, because the maximum supply is 1.0 MPa and the Standard type regulates to 0.9 MPa, there is only about 0.1 MPa of headroom above the top setting, so plan a supply near 1.0 MPa if you truly need 0.9 MPa out.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates in temperatures from -5 to 70 C, features a 60 cc drain bowl and a 98 cc oil bowl, uses ISO VG 32 lubricant, and weighs 1300 g.
The unit is fitted with both a semi-auto drain, which expels condensate during each pressure drop, and a manual drain for on-demand emptying. A circular gauge is pre-installed, reading in MPa and psi to match the default NPT threads, allowing direct monitoring of the regulated outlet pressure.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.