The AirTAC GAC F.R.L. Unit GAC300C08ASNTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for pneumatic machinery, this AirTAC GAC300C08ASNTK combines a filter, regulator and lubricator on a single L-shape bracket. The 1/4in port serves standard duties operating between 0.15-0.9 MPa (20-130 psi), passing air through a 40 um element. A metal bowl houses the 60 cc condensate sump and 98 cc oil reservoir.
Because the automatic drain clears accumulated water without an operator, the unit suits unattended or wet lines. The reverse-flow (reflux) valve is fitted, shown in the catalogue as a separate pneumatic symbol with details on its own page. No gauge is supplied, but a 1/8in connection allows adding one if the set pressure needs monitoring. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300C08ASNTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-08 filter, GAR300-08 regulator, GAL300-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/4" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Prepares air for CNC tool changers, ensuring the 1/4in line delivers stable pressure and oil mist to pneumatic grippers.
Conditions air for diverters and pushers on a packaging line, with the automatic drain handling moisture in high-duty cycles.
Feeds a localized drop on an assembly station, using the 40 um element to protect directional valves from pipe scale.
Choose this metal bowl configuration for harsher environments where polycarbonate might risk impact damage, keeping the shared 1.0 MPa max and -5 to 70 C limits. The automatic drain pairs well with the 60 cc sump for remote stations, while the missing gauge keeps the profile compact. If the downstream line must stay oil-free, omit the lubricator and choose a filter-regulator instead. Spares follow the body-port suffix exactly: GAF300-08, GAR300-08 and GAL300-08. Stepping down to the GAC200 halves the plotted flow envelope to 1750 L/min at 0.7 MPa inlet, whereas this GAC300 reaches 3000 L/min. The 1.5 MPa proof pressure provides a 1.5x burst-test margin above the 1.0 MPa maximum, though it is not permission to run above 1.0 MPa.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 1300 g, uses a 60 cc drain bowl and a 98 cc oil bowl, and requires ISO VG 32 lubricant.
The metal bowl offers a robust housing for the 60 cc condensate sump and 98 cc oil reservoir. The reflux valve is fitted as an ordering option, depicted as a separate pneumatic symbol in the catalogue, but no gauge is supplied out of the box.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.