The AirTAC GAC F.R.L. Unit GAC300C08LNWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this GAC300C08LNWTK assembly integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/4in port routes air through a 5 um element to capture fine particulates before the regulator steps the supply down to a 0.15-0.4 MPa (20-58 psi) lower-pressure range. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing residue from fouling the internal pressure controls.
Weighing 1300 g, the unit pairs a robust metal bowl with a 60 cc condensate sump and a 98 cc oil reservoir. No pressure gauge is supplied, but the body features a 1/8in gauge connection for adding instrumentation later. The assembly includes a reverse-flow (reflux) valve, which the catalogue illustrates as a separate pneumatic symbol with details on its own page. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300C08LNWTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-08 filter, GAR300-08 regulator, GAL300-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/4" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure instrument air to sensitive solenoid banks, relying on the 5 um element to prevent spool sticking in tight-tolerance valve bodies.
Regulates a gentle 0.15-0.4 MPa supply for delicate test fixtures, using the metal bowl to withstand chemically aggressive cleaning environments.
Conditions air for small-bag forming cylinders where a 1/4in port provides adequate flow without over-pressurizing delicate sealing jaws.
Choose this configuration when a circuit requires precision filtration and low operating pressures, as the 5 um element traps far finer particles than the standard 40 um grade, demanding more frequent element service in exchange. The metal bowl suits harsher industrial settings, while the semi-auto and manual drain pair handles condensate removal during regular pressure drops or on-demand operator intervention. If the downstream line must remain completely oil-free, omit the lubricator and select a dedicated filter-regulator instead. Should a component fail, the three units are separately orderable as GAF300-08, GAR300-08 and GAL300-08. Stepping up to the GAC400 body increases the condensate sump from 60 cc to 100 cc, whereas choosing this L type means the 0.4 MPa ceiling is 44% of the Standard type's 0.9 MPa maximum.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure type unit operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It features a 1/4in port, a 5 um element, a 60 cc drain bowl, a 98 cc oil bowl, and weighs 1300 g. The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32.
The N in the ordering code indicates no gauge is supplied, so the set pressure cannot be read without adding one. The body features a 1/8in gauge connection for installing a separate instrument, and the default NPT thread sets the scale to MPa/psi if a gauge is added later.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.