The AirTAC GAC F.R.L. Unit GAC300C08SNWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this AirTAC F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 1/4in ported GAC300 body carries a 5 um element that traps far finer particles than the standard 40 um grade, making it ideal for protecting precision valves and instrument air circuits.
This specific configuration features a robust metal bowl and operates within the 0.15-0.9 MPa (20-130 psi) standard pressure range. Because no gauge is supplied from the factory, operators must add one to the 1/8in gauge connection to read the set pressure. The 60 cc drain bowl and 98 cc oil reservoir dictate the maintenance frequency, while the build order ensures oil mist is introduced downstream of the regulator seat. Order code GAC300C08SNWT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300C08SNWT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-08 filter, GAR300-08 regulator, GAL300-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/4" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Supplies finely filtered, lubricated air to pneumatic tool change cylinders, where the 5 um element prevents sticking in precision tool holders.
Conditions air for high-speed packaging actuators, ensuring consistent regulator pressure for film sealing jaws operating at 0.15-0.9 MPa.
Prepares drive air for sensitive lab pneumatics, using the metal bowl and fine filtration to protect delicate valve internals from particulate ingress.
Choose this 1300 g assembly when a mid-size air preparation unit is required for a dedicated machine rather than a single small actuator. The metal bowl suits harsher industrial environments where polycarbonate might be at risk, and the semi-auto plus manual drain pair gives operators flexibility during system depressurization. If your downstream line must remain completely oil-free, omit the lubricator and select a separate filter-regulator instead.
The 5 um element provides superior protection for sensitive components but requires more frequent replacement than the 40 um standard. Spares are ordered individually as GAF300-08, GAR300-08 and GAL300-08. Stepping up to the GAC400 roughly doubles the flow envelope, plotting to 6000 L/min at 0.7 MPa inlet compared to this body's 3000 L/min curve, but the GAC300 holds a 1.5x overpressure margin with its 1.5 MPa proof pressure against the 1.0 MPa maximum.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, weighs 1300 g, features a 60 cc drain bowl and a 98 cc oil bowl, and requires an ISO VG 32 or equivalent lubricant.
The N in the ordering code indicates no gauge is supplied. The unit has a 1/8in gauge connection, allowing you to install a specific NPT-threaded gauge reading in MPa/psi that matches your operators' preferences.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.