The AirTAC GAC F.R.L. Unit GAC300N08ALNTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and oil-misted air for pneumatic systems, this GAC300N08ALNTK is a three-unit F.R.L. combination pre-plumbed on a single L-shape bracket. It features a 1/4in port, a 40 um element, and a lower pressure regulating range of 0.15-0.4 MPa (20-58 psi). The nylon bowl and automatic drain are paired with a reverse-flow valve, while the absence of a gauge leaves a 1/8in connection for adding one later.
Air passes through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. Weighing 1300 g, this assembly needs a proper panel or frame mount rather than relying on tubing support. The automatic drain clears condensate without an operator, which is decisive for unattended or wet lines, and the 60 cc drain bowl dictates the intervention frequency. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300N08ALNTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-08 filter, GAR300-08 regulator, GAL300-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/4" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeding delicate actuator circuits on electronics assembly fixtures where the 0.4 MPa ceiling prevents crushing fragile components.
Supplying regulated air to small bagging machines that rely on steady low pressure for consistent heat seal jaw actuation.
Conditioning air for benchtop fluid dispensing robots, using the automatic drain to handle condensate during unattended overnight runs.
This unit suits low-pressure duties where the machine ceiling is 0.4 MPa; if the application may ever need more, the L type is the wrong part. The 40 um element is standard, whereas a 5 um W variant traps finer particles for precision valves at the cost of more frequent service. Because no gauge is supplied, the set pressure cannot be read without adding one to the 1/8in connection. If the downstream line must stay oil-free, choose a filter-regulator instead of this lubricator-equipped assembly. The separate spares are GAF300-08, GAR300-08 and GAL300-08. Stepping up to the GAC400 body shifts the plotted flow envelope from 3000 to 6000 L/min at 0.7 MPa inlet, doubling the sizing capacity. The lower-pressure ceiling of 0.4 MPa is 44% of the standard 0.9 MPa maximum.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 1300 g, has a 60 cc drain bowl and a 98 cc oil bowl, and uses ISO VG 32 lubricant.
The K indicates a reverse-flow (reflux) valve is fitted, which the catalogue shows as a separate pneumatic symbol with details on its own page. This model also lacks a gauge, so you must add one to the 1/8in connection to read the set pressure.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.