The AirTAC GAC F.R.L. Unit GAC300N08ALT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, lubricated and precisely metered air, this AirTAC assembly integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/4in ported body operates on the lower pressure scale at 0.15-0.4 MPa (20-58 psi), utilizing a 40 um element to protect downstream pneumatics. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling of the internal pressure-control mechanism.
Weighing 1300 g, this unit pairs a 60 cc condensate bowl with a 98 cc oil reservoir to dictate maintenance frequency. The nylon bowl material is specified here, and the automatic drain actively purges collected water without operator intervention. A circular gauge is fitted, reading MPa/psi for the default NPT thread, allowing operators to verify the set pressure directly at the unit. Order code GAC300N08ALT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300N08ALT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-08 filter, GAR300-08 regulator, GAL300-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/4" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds delicate pneumatic clamps on electronics assembly fixtures where actuator force must stay below the 0.4 MPa ceiling to prevent component damage.
Conditions air for small bagging machines, using the automatic drain to clear condensate continuously during high-cycle shift operations.
Supplies stable low-pressure air to laboratory test benches, ensuring sensitive metering valves receive 40 um filtered, lubricated air.
Choose this configuration for unattended lines requiring consistent low-pressure regulation, where the automatic drain leverages the 60 cc capacity to reduce manual visits. If a machine ever requires pressure above 0.4 MPa, this lower-pressure type is the wrong part, as the standard type regulates up to 0.9 MPa. The 40 um element suits general actuator protection, while the fitted gauge allows immediate visual confirmation of the 0.15-0.4 MPa range. Should a component fail, order the GAF300-08 filter, GAR300-08 regulator and GAL300-08 lubricator separately rather than replacing the whole set. Note that if the downstream line must remain oil-free, you must omit the lubricator and choose a filter-regulator instead. Stepping up to the GAC400 body increases the condensate capacity from 60 cc to 100 cc, but choosing this L type means the 0.4 MPa ceiling is 44% of the standard 0.9 MPa maximum.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) and carries a max pressure of 1.0 MPa (145 psi) with a 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, weighs 1300 g, holds 60 cc of condensate and 98 cc of oil, and uses ISO VG 32 lubricant.
The A in the ordering code specifies an automatic drain that empties the 60 cc bowl without an operator, which is ideal for wet or unattended lines. The N before the port designates the nylon bowl material, distinct from the N used after the port for no gauge.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.